OPERATING THE ENGINE
14
A
Do not operate the tractor under full load condition until
it is sufficiently warmed up.
JUMP STARTING
To avoid personal injury:
A
Battery gases can explode. Keep cigarettes,
sparks, and flames away from battery.
A
If tractor battery is frozen, do not jump start
engine.
A
Do not connect other end of negative (-) jumper
cable to negative (-) terminal of tractor battery.
When jump starting engine, follow the instructions below
to safely start the engine.
1. Bring helper vehicle with a battery of the same voltage
as disabled tractor within easy cable reach. "THE
VEHICLES MUST NOT TOUCH".
2. Engage the parking brakes of both vehicles and put
the shift levers in neutral. Shut both engines off.
3. Put on safety goggles and rubber gloves.
4. Ensure the vent caps are securely in place. (if
equipped)
5. Cover vent holes with damp rags. Do not allow the rag
to touch the battery terminals.
6. Attach the red clamp to the positive (red, (+) or pos.)
terminal of the dead battery and clamp the other end
of the same cable to the positive (red, (+) or pos.)
terminal of the helper battery.
7. Clamp the other cable to the negative (black, (-) or
neg.) terminal of the helper battery.
8. Clamp the other end to the engine block or frame of
the disabled tractor as far from the dead battery as
possible.
9. Start the helper vehicle and let its engine run for a few
moments. Start the disabled tractor.
10.Disconnect the jumper cables in the exact reverse
order of attachment. (Steps 8, 7 and 6).
11.Remove and discard the damp rags.
A
This machine has a 12 volt negative (-) ground starting
system.
A
Use only same voltage for jump starting.
A
Use of a higher voltage source on tractor's electrical
system could result in severe damage to tractor's
electrical system.
Use only matching voltage source when "Jump
starting" a low or dead battery condition.
A
Do not operate the tractor with the battery cable
disconnected from the battery.
A
Do not operate the tractor without the battery
mounted.
A
Do not operate the tractor with the battery dead.
Charge the battery fully enough before operating the
tractor.
Otherwise the tractor might malfunction.
Ambient temperature
Warm-up time requirement
Higher than -10
(14
)
Approx. 10 minutes
-15 to -10
(5 to 14
)
10 to 20 minutes
-20 to -15
(-4 to 5
)
20 to 30 minutes
Below -20
(-4
)
More than 30 minutes
(1) Dead battery
(2) Lay a damp rag over the vent caps
(3) Jumper cables
(4) Helper battery
Summary of Contents for M7040SU
Page 15: ...7 SAFE OPERATION 7 DANGER WARNING AND CAUTION LABELS ...
Page 16: ...SAFE OPERATION 8 ...
Page 17: ...9 SAFE OPERATION ...