• The DPF regeneration cycle only starts in the
following conditions. If any of the conditions
are not met, the DPF regeneration cycle may be
interrupted.
Coolant temperature
above 65
℃
DPF temperature
above 250
℃
Engine rpm
above 1200 rpm
• The DPF regeneration usually takes about the
following times.
DPF regeneration time
15 minutes to 20 minutes
The DPF regeneration time depends, however,
on the outside air temperature, exhaust gas
temperature and filter PM level.
• Do not interrupt the DPF regeneration cycle
unnecessarily.
EXHAUST AFTERTREATMENT DEVICE