• When draining fluids from the engine, place
some container underneath the engine body.
• Do not pour waste onto the ground, down a
drain, or into any water source.
• Also, follow the relevant environmental
protection regulations when disposing of the
antifreeze.
Always use a 50/50 mix of long-life coolant and clean
soft water in KUBOTA engines.
Consult your local KUBOTA Dealer concerning coolant
for extreme conditions.
NOTE :
• The following data represent industry standards
that necessitate a minimum glycol content in
the concentrated antifreeze.
• Long-life coolant (hereafter LLC) comes in several
types. Use ethylene glycol (EG) type for this
engine.
• Before using LLC-mixed cooling water, fill the
radiator with fresh water and empty it again.
Repeat this procedure 2 times or 3 times to clean
up the inside.
• Mixing the LLC
Premix
50% LLC with 50% clean soft water.
When mixing, stir it up well, and then fill into the
radiator.
• Adding the LLC
– Add only water if the mixture reduces in amount
by evaporation.
– If there is a mixture leak, add the LLC of the
same manufacturer and type in the same
mixture percentage.
• Never add any long-life coolant of different
manufacturer. Different brands may have
different additive components, and the
engine may fail to perform as specified.
• When the LLC is mixed, do not use any radiator
cleaning agent. The LLC contains anticorrosive
agent. If mixed with the cleaning agent, sludge may
build up, adversely affecting the engine parts.
• KUBOTA's genuine long-life coolant has a service
life of 2 years. Be sure to change the coolant as
follows.
Changing the coolant
every 2000 hours or every 2 years
whichever comes faster
• The procedure for the mixing of water and the
antifreeze differs according to the make of the
antifreeze and the ambient temperature. Refer to
SAE J1034 standard, more specifically also to SAE
J814c.
Antifreeze
Freezing point
Boiling Point
*1
50Vol%
-37
℃
-34
℉
108
℃
226
℉
*1
At 1.013 x 10
5
Pa (760 mmHg) atmospheric pressure. A higher
boiling point is obtained by using a radiator pressure cap which
permits the development of pressure within the cooling system.
SERVICE EVERY 3000 HOURS
1. Checking the injection pump
• Consult your local KUBOTA Dealer for checking the
injection pump.
SERVICE EVERY 1 YEAR
1. Checking the intake air line
WARNING
To avoid serious injury or death:
• Stop the engine and remove the key before
checking the intake air line.
1. Check to see that the hose and the hose clamps
are tight and not damaged.
PERIODIC SERVICE
SERVICE EVERY 3000 HOURS
94
BX1880, BX2380, BX2680
Summary of Contents for BX1880-AU
Page 15: ...SAFETY LABELS SAFE OPERATION BX1880 BX2380 BX2680 11 ...
Page 16: ...SAFE OPERATION 12 BX1880 BX2380 BX2680 ...
Page 17: ...SAFE OPERATION BX1880 BX2380 BX2680 13 ...
Page 18: ...SAFE OPERATION 14 BX1880 BX2380 BX2680 ...
Page 20: ...SAFE OPERATION 16 BX1880 BX2380 BX2680 ...
Page 62: ... 1 Hitch 3 POINT HITCH AND DRAWBAR 58 BX1880 BX2380 BX2680 ...