PERIODIC SERVICE
58
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal and
the negative to the negative, then recharge in the
standard fashion.
2. A boost charge is only for emergencies. It will partially
charge the battery at a high rate and in a short time.
When using a boost-charged battery, it is necessary to
recharge the battery as early as possible.
Failure to do this will shorten the battery's service life.
3. The battery is charged if the indicator display turns
green from black.
4. When exchanging an old battery for a new one, use
battery of equal specification shown in
table 1
.
[TABLE 1]
C
Battery Storage
1. When storing the tractor for long periods of time,
remove the battery from tractor, adjust the electrolyte
to the proper level and store in a dry place out of direct
sunlight.
2. The battery self-discharges while it is stored.
Recharge it once every three months in hot seasons
and once every six months in cold seasons.
B
Cleaning Air Cleaner Primary Element
1. Remove the air cleaner cover and primary element.
2. Clean the primary element:
(1) When dry dust adheres to the element, blow
compressed air from the inside, turning the
element. Pressure of compressed air must be
under 205 kPa (2.1 kgf/cm , 30 psi).
(2) When carbon or oil adheres to the element, soak
the element in detergent for 15 minutes then wash
it several times in water, rinse with clean water
and dry it naturally. After element is fully dried,
inspect inside of the element with a light and
check if it is damaged or not.
3. Replace air cleaner primary element:
Once yearly or after every sixth cleaning, whichever
comes first.
A
Check to see if the evacuator valve is blocked with
dust.
A
The air cleaner uses a dry element, never apply oil.
A
Do not run the engine with filter element removed.
A
Be sure to refit the cover with the arrow
(on the rear
of cover) upright. If the cover is improperly fitted,
evacuator valve will not function and dust will adhere
to the element.
A
Do not touch the secondary element except in cases
where replacing is required.
(See "Replacing Air Cleaner Secondary Element" in
"EVERY 1 YEAR" in "PERIODIC SERVICE" section.)
C
Evacuator Valve
Open the evacuator valve once a week under ordinary
conditions - or daily when used in a dusty place - to get rid
of large particles of dust and dirt.
(1) Battery
Battery
Type
Volts
(V)
Capacity
at
5H.R
Reserve
at
(min)
Cold
Cranking
Amps
Normal
Charging
Rate(A)
55B24L
(S)-MF
12
36
80
430
4.5
(1) Secondary (safety) element
(2) Primary element
(3) Cover
(4) Evacuator valve
Summary of Contents for B2320
Page 1: ......
Page 14: ...SAFE OPERATION 6 7 DANGER WARNING AND CAUTION LABELS ...
Page 15: ...7 SAFE OPERATION ...