Section 1: Assembly & Set-up
4/5/19
AP-SRF2772, AP-SRF2790, AP-SR2772, & AP-SR2790 Powered Rakes 321-120MK
18
Control Switch & Wire Harness With Eyelets
Figure 1-12
Control Harness With 2 Eyelets
323-097A . . . . . . . . . . . . SWITCH & WIRE HARNESS
Refer to Figure 1-12:
This switch and wire harness is designed for attaching
the Powered Rake to a skid steer without a 2 pin or 14 pin
Deutsch plug. The 2 push button control switch (#9) can
be placed approximately 9 ft. from the solenoid valve.
1.
Disconnect negative (-) black ground wire from the
skid steer’s battery post (not shown).
2.
Attach positive (+) red wire eyelet (A) to a 12 volt
power source. Tighten fastener hardware.
3.
Attach negative (-) black wire eyelet (B) to ground.
Tighten fastener hardware.
4.
Reconnect negative (-) black ground wire to the skid
steer’s battery. Tighten fastener hardware.
5.
The push button control switch (#9) is mounted using
magnets on the back. Locate and mount this switch
in a convenient easy to reach location.
6.
Connect power cord (#8) to control switch wire (#7).
7.
Connect green wire plug (#1) to the top solenoid
connector (#2).
8.
Connect red wire plug (#3) to the bottom solenoid
connector (#4).
9.
Zip ties (#5) will be installed later.
10. Continue with
“Operational Check”
on this page.
39768
NOTE:
Additional zip ties may be needed to
properly secure all wiring harness. Customer to
supply and locate all additional zip ties.
Operational Check
Refer to Figure 1-10:
1.
With hydraulics hooked-up, start skid steer and press
buttons to angle rake.
2.
If rake angles in opposite direction desired, switch
plugs (#1 & #3) with solenoid connectors (#2 & #4).
3.
If everything is working correctly, secure
harness (#6) near the solenoid valve with zip tie (#5).
4.
Make certain hydraulic hoses from skid steer to rake
are kept away from all pinch points.
5.
Tie hydraulic hoses and electrical cables together as
needed with zip ties (#5).