Manual
Limes LA10 / BA1
Absolute Magnetic Length Measurement System
7.7.2 CANopen Interface
M12 connector PIN
Option CAN
Option CAN
Incremental TTL
1
0V/GND
0V/GND
2
+ 10-30 VDC
+ 10-30 VDC
3
CAN low
CAN low
4
CAN high
CAN high
5
not assigned
not assigned
6
not assigned
not assigned
7
not assigned
C
8
not assigned
Cosinus -
9
not assigned
Sinus +
10
not assigned
Sinus -
11
not assigned
not assigned
12
not assigned
not assigned
Shield
PE*
PE*
*) Connect shield only at the device!