KTR-STOP
®
XS-A-F B-xx
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
445118 EN
23 of 23
1
Please observe protection
note ISO 16016.
Drawn:
2020-12-03 Shg/Mro
Replacing:
---
Verified:
2020-12-03 Shg
Replaced by:
Technical data:
Operating temperature
-40 °C to +85 °C
Max. voltage
30 V DC/AC
Switching current
100 mA
Protection class
IP 65 (mounted)
Width across flats
24 mm
Max. tightening torque G 1/2
20 Nm
Max. tightening torque M12
hand-tight
Length of cable
5 m, 10 m or 15 m
Material of cable
PUR
Dimension of cable
5 * 0,34 mm
2
Illustration 24: Pin assignment of plug-in connection
•
Remove the screw plug from the brake.
•
Screw the sensor hand-tight into the brake for the time
being (see illustration 25).
•
Tighten the sensor at the tightening torque
T
A
= 20 Nm.
•
Provide for the electric connection according to the
plug-in connection (see illustration 24).
Illustration 25: Assembly of pre/end wear sensor
6
Accessories - Sensor
6.1
Technical data „Pre-/end wear sensor”
6.2 Assembly / start-up