WORK
8
Info
Even when there is no load on the battery, it still loses power steadily.
The charge state and the type of charge are very important for the service life of the battery.
Rapid recharging with a high charging current shortens the battery's service life.
If the charging current, charging voltage and charging time are exceeded, electrolyte escapes through the safety valves. This
reduces the battery capacity.
If the battery is depleted from starting the vehicle repeatedly, the battery must be charged immediately.
If the battery is left in a discharged state for an extended period, it will become over-discharged and sulfate, destroying the
battery.
The battery is maintenance-free, which means that the acid level does not need to be checked.
–
Switch off all power consumers and switch off the engine.
–
Remove the seat. (
–
Disconnect the negative cable of the battery to avoid damage to the onboard elec-
tronics.
400240-10
–
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (58429074000)
You can also use the battery charger to test the open-circuit voltage and starting
voltage of the battery, and to test the alternator. With this device, you cannot over-
charge the battery.
Info
Never remove lid
.
Charge the battery with a maximum of 10% of the capacity specified on the
battery housing
.
–
Switch off the battery charger after charging. Disconnect the battery.
Guideline
The charge current, charge voltage and charge time must not be exceeded.
Charge the battery regularly when the
motorcycle is not in use
3 months
–
Mount the seat. (
3.8
Opening the filler cap
B00277-10
–
Press release button
, turn the filler cap counterclockwise and lift it free.
3.9
Closing the filler cap
B00278-10
–
Replace the filler cap and turn clockwise until the release button
locks in place.
Info
Run the fuel tank breather hose
without kinks.