3.  Making Connections

3.1  Making UTP Connections

The copper ports support the following connection types and distances:

Network Cables

10BASE-T:

2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm

100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm
Link distance:

Up to 100 meters

Auto MDI/MDI-X Function

This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid
MDI to MDI-X connection with the remote connected device automatically. No matter a straight
through cable or crossover cable is connected, the ports can sense the receiving pair automatically and
configure itself to match the rule for MDI to MDI-X connection. It simplifies the cable installation.

Auto-negotiation Function

The ports are featured with auto-negotiation function and full capability to support connection to any
Ethernet devices. The port performs a negotiation process for the speed and duplex configuration with
the connected device automatically when each time a link is being established. If the connected device
is also auto-negotiation capable, both devices will come out the best configuration after negotiation
process. If the connected device is incapable in auto-negotiation, the switch will sense the speed and
use half duplex for the connection.

3.2  Making Fiber Connection

The SFP slot must be installed with an SFP fiber transceiver for making fiber connection. Your
switch may come with an SFP transceiver pre-installed when it is shipped.

To install an SFP fiber transceiver into the SFP slot, the steps are:
1. Turn off the power to the switch.

2. Insert the SFP fiber transceiver into the SFP slot. Normally, a bail is provided for every SFP

transceiver. Hold the bail and make insertion.

3.  Until the SFP transceiver is seated securely in the slot, place the bail in lock position.

4. Turn on the power to the switch.

Connecting Fiber Cables

LC connectors are commonly equipped on most SFP transceiver modules. Identify TX and RX
connector before making cable connection. The following figure illustrates a connection example
between two fiber ports:

Make sure the Rx-to-Tx connection rule is followed on the both ends of the fiber cable.

Network Cables

Multimode (MMF) - 50/125, 62.5/125
Single mode (SMF) - 9/125

Summary of Contents for KSD-541

Page 1: ... 1 Industrial 5 Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model KSD 541 PoE Model KSD 541 P Installation Guide DOC 100125 ...

Page 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 2...

Page 3: ...or compliance could void the user s authority to operate the equipment 2 Shielded interface cables and AC power cord if any must be used in order to comply with the emission limits CISPR A COMPLIANCE This device complies with EMC directive of the European Community and meets or exceeds the following technical standard EN 55022 Limits and Methods of Measurement of Radio Interference Characteristics...

Page 4: ...ty Cautions 9 2 3 Mounting the Switch on a Wall 9 2 4 Din Rail Mounting 10 2 5 Panel Mounting 11 2 6 Applying Power 11 3 Making Connections 13 3 1 Making UTP Connections 13 3 2 Making Fiber Connection 13 3 3 Making PoE Connections 14 3 4 LED Indication 15 4 Applications 16 4 1 Applications with Basic Switch Model 16 4 2 Applications with PoE Switch Model 17 ...

Page 5: ...ect and configure the connection speed and duplex automatically The switch also provides auto MDI MDI X function which can detect the connected cable and switch the transmission wire pair and receiving pair automatically This auto crossover function can simplify the type of network cables used Fiber Connectivity For fiber connection the SFP slot can be installed with an optional SFP optical fiber ...

Page 6: ...our IEEE 802 3af compliant PoE PSE ports z Provides two types of power supply interfaces DC Jack and terminal block z Supports stand alone wall Din Rail and panel mounting z Industrial rated emission and immunity performance 1 2 Product Panels The following figure illustrates the faces of the switch 1 3 LED Indicators LED Function POWER Power status LINK ACT Port link status and activities Port 1 ...

Page 7: ...Copper Interface Connector Shielded RJ 45 jack Pin assignments Auto MDI MDI X detection Configuration Auto negotiation or software control Transmission rate 10Mbps 100Mbps Duplex support Full Half duplex Network cable Cat 5 UTP Fiber Interface Connector SFP slot for optional SFP type fiber transceivers Configuration 100Mbps Full duplex Far End Fault Support Enabled Network cables MMF 50 125 60 125...

Page 8: ...ock screw type Operating Input Voltages 6 60VDC Power Consumption 3W max 7 5V No PoE output PoE Function Operating input voltage 43V 54V Typical 48V DC IN Jack Interfaces Power jack D 6 3mm D 2 0mm DC IN Terminal Block Pins GND Mechanical Dimension base 144 x 104 5 x 26 mm Housing Enclosed metal with no fan Mounting Support Din rail mounting Panel mounting Wall mounting Desktop mounting Environmen...

Page 9: ...cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings of your system Doing so can cause fire or electric shock by shorting out interior components Operate the product only f...

Page 10: ...Mounting The steps to mount the switch on aDin rail are One Din rail mounting bracket is provided in the product package as shown below Install the bracket on the bottom of the switch unit Mount the device on a Din rail ...

Page 11: ...n below Install the bracket on the bottom of the switch unit The final dimension after panel bracket is installed is shown below 2 6 Applying Power The switch provides two types of power interfaces terminal block and DC power jack for receiving DC power input from external power supply system ...

Page 12: ...s a DC jack to receive power from typical AC DC power adapter alternatively AC Power Adapters Optional commercial rated adapters are available for purchasing Non PoE applications Rated output DC7 5V 0 5A 1A 1 2A PoE applications Rated input 100V 240VAC Output 48VDC 24W About 20 21W is reserved for PoE PDs connected Note Before you begin the installation check the AC voltage of your area The AC pow...

Page 13: ... If the connected device is also auto negotiation capable both devices will come out the best configuration after negotiation process If the connected device is incapable in auto negotiation the switch will sense the speed and use half duplex for the connection 3 2 Making Fiber Connection The SFP slot must be installed with an SFP fiber transceiver for making fiber connection Your switch may come ...

Page 14: ...N power voltage supplied to the switch must be within the following range to make PoE function working DC IN voltage range for PoE applications 43V 54V 4 The DC IN power supplied to the switch must meet the following calculation DC IN power Sum of all connected PD power required 3 watts The PSE ports are equipped with the following capabilities 1 Detection for an IEEE 802 3af compliant PD 2 No pow...

Page 15: ... Port link status ON A port link is established No traffic BLINK Port link is up and there is traffic OFF Port link is down 100M 10M Port speed status ON Speed 100M is selected OFF Speed 10M is selected PoE STATUS Port PoE power ON PoE power is delivered on the port OFF PoE power is shut down SFP RJ 45 Port1 status ON SFP is used on Port 1 OFF RJ 45 is used on Port 1 ...

Page 16: ...sic Switch Model The following figure illustrates a basic switch model connects five computers via Cat 5 cables The following figure illustrates a basic switch model connects four computers via Cat 5 cables and uplink to a fiber backbone network ...

Page 17: ...l The figure below illustrates a PoE switch connects four PoE IP cameras via Cat 5 cables and uplinks to a fiber backbone The figure below illustrates a PoE switch connects four PoE WLAN access points via Cat 5 cables and uplinks to a backbone ...

Page 18: ... 18 The figure below illustrates a PoE switch powered by a 48V DC power adapter connects four PoE media converters via Cat 5 cables and uplinks to a fiber backbone ...

Reviews: