background image

-5- 

Mechanical 

Dimension (base) 

40 x 80 x 95 mm (WxDxH) 

Housing Enclosed 

metal 

Mounting 

Din-Rail mounting, Panel mounting, Desktop mounting 

 

Environmental 

Operating Temperature  KPW-2012-D: 

20

o

C ~

50

o

 KPW-2012-D-E: 

20

o

C ~

60

o

Storage Temperature 

30

o

C ~

85

o

Relative Humidity 

10% ~ 90% non-condensing 

 

Internal Power Module Approvals 

Safety Certification 

UL60601-1 

 IEC60601-1 

 

TUV EN60601-1 Certified 

 

Electrical Approvals 

FCC 

Part 15 rule Class A 

CE EMC 

EN55022:2006/A1:2007 

  

EN61000-3-2:2006 

 

 

EN61000-3-3:1995/A1:2001/A2:2005 Class A 

 EN 

55024:1998/A1:2001/A2:2003 

  

EN 

61000-4-2:2001 

  

EN 

61000-4-3:2002/A1:2002 

  

EN 

61000-4-4:2004 

  

EN 

61000-4-5:2001 

  

EN 

61000-4-6:2003 

  

EN 

61000-4-8:2001 

  

EN 

61000-4-11:2001 

Safety LVD, 

IEC60950-1 

 

MTBF 

400K Hours 

Summary of Contents for KPW-2012-D

Page 1: ...KPW 2012 D x Din Rail AC DC 12V Power Supply User s Manual DOC 091217 1 ...

Page 2: ...es the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 269...

Page 3: ...d including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC Class A EN55022 2006 A1 2007 EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 Class A EN 55024 1998 A1 2001 A2 2003...

Page 4: ...0 240VAC No load Consumption 0 75W DC Power Output Interfaces Type 1 Screw type terminal block Vout Vout Vout Vout Type 2 DC plug with bundled DC plug cable Output Power 12VDC 1 8A max Power Specification KPW 2012 D 100 20o C 50o C 50 60o C KPW 2012 D E 100 20o C 60o C Protection Short Circuit Overload Over Voltage 4 ...

Page 5: ...umidity 10 90 non condensing Internal Power Module Approvals Safety Certification UL60601 1 IEC60601 1 TUV EN60601 1 Certified Electrical Approvals FCC Part 15 rule Class A CE EMC EN55022 2006 A1 2007 EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 Class A EN 55024 1998 A1 2001 A2 2003 EN 61000 4 2 2001 EN 61000 4 3 2002 A1 2002 EN 61000 4 4 2004 EN 61000 4 5 2001 EN 61000 4 6 2003 EN 61000 4 8 ...

Page 6: ...ns occur unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions z Do not push any objects into the...

Page 7: ...Din Rail Mounting Install the Din Rail bracket on the rear panel as shown below Mount the device unit on a Din Rail as shown below 7 ...

Page 8: ...Final Dimension after Installation Panel Mounting An optional panel mounting bracket supports mounting the power supply on a plane surface securely 8 ...

Page 9: ...Install the bracket onto the device unit as shown below and use two screw holes to fix the unit on a plane surface Final Dimension after Installation 9 ...

Page 10: ... and terminal block for receiving AC power input Using Terminal Block Use 3P terminal plug for AC power wires Install the wires into the plug securely The colors of the power wires are Contacts Europe IEC USA L Life Brown Black N Neutral Blue White PE Earth Green Yellow Green 10 ...

Page 11: ... cap to cover the unused IEC320 receptacle Using IEC320 Interface One AC power cord which meets the specification of your country of origin is supplied in package Plug the power cord into the IEC320 receptacle properly For safety purpose put the supplied caps on the unused AC terminal block 11 ...

Page 12: ...ical DC plug support for commercial installation Using Terminal Blocks DC OUT 2P x 2 Contacts Vout terminal Vout terminal Vout terminal Vout terminal Vout 12VDC 1 8A total max Use the supplied 2P plug for DC power wires Insert and screw the wires securely as shown below Power wire specification 24 12AWG IEC 0 5 2 5mm2 12 ...

Page 13: ...plug into DC OUT socket as shown below and put cap on any unused DC OUT contacts Using DC plug cable To support the devices which have only DC IN Jack interface one DC plug cable shown below is supplied DC Plug Cable 13 ...

Page 14: ...Insert the cable into DC OUT terminal block of the power unit as illustrated below and uncover any unused contacts An Example of supplying power to a device with DC Jack 14 ...