-35-
>IPv6
AUTOCONFIG
[Enable|disable]
>IPv6 Setup [<ipv6_addr>][<ipv6_prefix>][<ipv6_router>][<vid>]
Note: <vid> means VLAN ID.
The keywords and parameters are same as described in section 3.2 and section 3.3.
3.5 Reference Manuals for Web, Console, Telnet Management
The following operation manuals are also provided separately for Console, Telnet and Web management:
Operation manual - telnet & console management xxxxxx.doc
Operation manual - web management xxxxx.doc
The manuals describe the detailed commands and information.
3.6 Configuration for SNMP Management
The switch supports SNMP v1, SNMP v2c, and SNMP v3 management. Make sure the related settings are
well-configured for the switch before you start the SNMP management from an SNMP manager.
Using Telnet Interface
Master>Security>Switch>SNMP
Configuration
The following are available commands in telnet SNMP command group to configure SNMP-related settings:
>SNMP
Configuration
>SNMP Mode [enable|disable]
>SNMP Version [1|2c|3]
>SNMP Read Community [<community>]
>SNMP Write Community [<community>]
>SNMP Trap Mode [enable|disable]
>SNMP Trap Version [1|2c|3]
>SNMP Trap Community [<community>]
>SNMP Trap Destination [<ip_addr_string>]
>SNMP Trap IPv6 Destination [<ipv6_addr >]
>SNMP Trap Authentication Failure [enable|disable]
>SNMP Trap Link-up [enable|disable]