background image

-7- 

1.2 Features 

 

Eight 10/100/1000Mbps RJ-45 and four dual-speed SFP slots 

 

All copper ports support auto-negotiation and auto-MDI/MDI-X detection. 

 

Four SFP slots support dual speed for 100BASE-FX and 1000BASE-X SFP transceivers. 

 

Full wire speed forwarding 

 

Supports 802.3x flow control for full-duplex and backpressure for half-duplex 

 

Supports SFP with Digital Diagnostic Monitoring (DDM) 

 

Supports redundant power inputs 

 

Provides fiber Optical Power Alarm (OPA) function 

 

Provides Automatic Laser Shutdown (ALS) function 

 

Management: 

- HTTP/HTTPS/SSHv2/CLI telnet/CLI console/SNMP v1/v2c/v3/RMON 

- DHCP/DHCPv6 client, DHCP relay, DNS client, NTPv4 

- IPv6 support, System Syslog, Configuration down/upload, Software upload 

 

Security: 

- NAS, 802.1X, MAC-based/Web/CLI authentication 

- IP MAC binding, , IP source guard 

 

Layer 2: 

- QoS, 802.1Q/MAC-based/Protocol-based/Private/IP subnet VLAN, Port Isolation 

- Storm control for UC/MC/BC packets, Static MAC configuration 

- IGMP v2/v3 snooping, MLD v1/v2 snooping, DHCP snooping 

- Multiple Spanning Tree - MSTP. RSTP, STP 

 

Auto Multi-Ring (KAMR) Technology: 

- Fast failover response time 

- Auto recovery when failure is repaired 

- Supports up to five redundant rings 

- Works with RSTP network 

 

Specific SNMP implementation: 

- Private MIB for reading DDM status 

- Private MIB for remote boot the device over SNMP 

- Private MIB for TFTP firmware update over SNMP 

- Private MIB for configuring OPA function 

- Private MIB for configuring ALS function 

- OPA alarm traps 

Summary of Contents for KGS-1260/G

Page 1: ... 1 KGS 1260 G Basic KGS 1260 I IEC 61850 3 enhanced Industrial Managed 12 port Gigabit Ethernet Switches Installation Guide DOC 180817D ...

Page 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 2...

Page 3: ... not cause harmful interference and 2 This device must accept any interference received including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive 2014 30 EU of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC EN 55032 Class A CI...

Page 4: ...rm Relay Output 19 2 7 Reset Button 20 3 Making LAN Connections 21 3 1 10 100 1000 TP Copper Port 21 3 2 Making Fiber Connection 22 3 3 Making Console Connection 23 3 4 LED Indication 25 4 Manage the Switch 26 4 1 IP Address Password 26 4 2 Configuring IP Address Password via console and telnet 26 4 3 Configuring IP Address via Web Interface 27 4 4 Reference Manuals for Web Console Telnet Manageme...

Page 5: ... 5 5 1 Auto Multi Ring Technology 33 5 2 Redundant Ring Applications with industrial standard RSTP protocol 34 ...

Page 6: ...nication ports Eight 10 100 1000Mbps Gigabit copper ports Four dual speed SFP slots for 100Base FX 1000Base X One RS 232 console port 1 1 Model Definitions Model Description IEC 61850 3 IEEE 1613 Enhanced KGS 1260 G Industrial Managed 12 port Gigabit Ethernet Switch N A KGS 1260 I IEC 61850 3 Managed 12 port Gigabit Ethernet Switch Yes ...

Page 7: ...ient NTPv4 IPv6 support System Syslog Configuration down upload Software upload Security NAS 802 1X MAC based Web CLI authentication IP MAC binding TACACS IP source guard Layer 2 QoS 802 1Q MAC based Protocol based Private IP subnet VLAN Port Isolation Storm control for UC MC BC packets Static MAC configuration IGMP v2 v3 snooping MLD v1 v2 snooping DHCP snooping Multiple Spanning Tree MSTP RSTP S...

Page 8: ... negotiation or software control Transmission rate 10Mbps 100Mbps 1000Mbps Duplex support Full Half duplex Network cable Cat 5 UTP Dual speed SFP Slots Port 9 Port 12 Compliance IEEE 802 3u 100Base FX IEEE 802 3z 1000Base SX LX mini GBIC Connectors SFP for optional SFP type fiber transceivers Configuration Auto 1000Mbps Full duplex Forced 100Mbps Full duplex Transmission rate 100Mbps and 1000Mbps ...

Page 9: ...put A 3 B DC power input B 4 B DC power input B Redundancy Input A Input B Power input voltages 12 60VDC Power consumption 8 5W max 24V Protection Polarity Reversal shutdown Isolation Power lines vs frame ground Alarm Relay Output Terminal Block Pin assignments 3 terminal contacts 30VDC 1A max or 120VAC 0 5A max Pin Marking Alarm Relay Output contacts 1 2 AR NO NO pair Normal open Alarm shorted 2 ...

Page 10: ...wer substation Enhanced model LVD IEC60950 1 Safety IEC 60068 2 64 Vibration IEC 60068 2 27 30G Shock test Management Management Web based browser interface SNMP manager Port Control Operating mode Flow control LLDP Packet Filtering 802 1Q tagged packet filtering Untagged packet filtering 802 1Q VLAN Ingress 802 1Q tag stripping Egress 802 1Q tagging tag insertion S tag tagging 802 1ad double tagg...

Page 11: ...on Class A C 6 7 4 EN 55022 LAN conducted emission Class A C 6 7 4 EN 55022 Radiated emission Class A C 6 7 3 IEC 61000 4 2 ESD 15kV Air 8kV Contact C 6 7 3 IEC 61000 4 3 RS 10V m C 6 7 3 IEC 61000 4 4 EFT DC IN LAN 4kV C 6 7 3 IEC 61000 4 5 Surge DC IN 1kV LAN 4kV C 6 7 3 IEC 61000 4 6 CS DC IN LAN 10V C 6 7 3 IEC 61000 4 8 PFMF 100A m 1000A m C 6 7 3 IEC 61000 4 11 AC DIP N A No AC input in the ...

Page 12: ...1ms 3 axis C 6 10 Shock bump Class 2 20Gn 16ms 1000 axis C 6 10 Seismic Class 2 x 2Gn y 1Gn 10min C 6 10 Enclosure protection Ingress of solid foreign subjects 2 5mm IEEE 1613 Test Specifications IEEE 1613 Test Level Clause 4 1 DC rated control power inputs 80 100 Max DC IN Clause 4 2 Ripple on DC power input 10 Clause 4 3 AC rated control power inputs N A No AC input in the device Clause 5 2 Diel...

Page 13: ...der The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings of your system Doing so can cause fire or electric shock by shorting out interior components Operate the ...

Page 14: ...he steps to mount the switch onto a DIN rail are 1 1287BInstall the mounting bracket onto the switch unit as shown below 2 1288BAttach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail 3 1289BClamp the unit to the DIN rail and make sure it is mounted securely ...

Page 15: ... 15 KGS 1260 G and KGS 1260 I have the same dimension as follows ...

Page 16: ...ing bracket The bracket supports mounting the switch on a plane surface securely The mounting steps are 1 1290BInstall the mounting bracket on the switch unit 2 1291BScrew the bracket on the switch unit 3 1292BScrew the switch unit on a panel Three screw locations are shown below ...

Page 17: ... 17 KGS 1260 G and KGS 1260 I have the same dimension as follows ...

Page 18: ...er sources 2 5 1 DC power Terminal Block Connector European 4P terminal block plug DC Power input contacts Redundant input A B Pin 1 A DC power input A terminal 2 A DC power input A terminal 3 B DC power input B terminal 4 B DC power input B terminal DC power input voltages 12 60VDC Power consumption 8 5W max 24V Power wires 24 12AWG IEC 0 5 2 5mm2 Wire length 1 meter max Protection Polarity Rever...

Page 19: ...arm relay output NO Normal Open contacts Normal Open Alarm Shorted NO 2 3 Alarm relay output NC Normal Close contacts Normal Shorted Alarm Open NC The relay output can connect relay monitoring system Both of NO and NC logic are provided individually for logic selection Alarm Events Input power failure Configured port link fault OPA alarm Note Be sure the voltage applied on the relay contacts is wi...

Page 20: ...set the device without turning off the power Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are Operation Function Press the button and release during operation Reset boot up the device The behavior is same as power boot procedure Press the button when boot up until all LEDs blink Boot resto...

Page 21: ...r all above Auto MDI MDI X Function This function allows the port to auto detect the twisted pair signals and adapts itself to form a valid MDI to MDI X connection with the remote connected device automatically No matter a straight through cable or crossover cable are connected the ports can sense the receiving pair automatically and configure themselves to match the rule for MDI to MDI X connecti...

Page 22: ...ction The SFP slots FX port must be installed with an SFP fiber transceiver for making fiber connection Your device may come with an SFP transceiver pre installed when it was shipped Installing SFP Fiber Transceiver To install an SFP fiber transceiver into SFP slot the steps are 1 Turn off the power to the device unit 2 Insert the SFP fiber transceiver into the SFP slot Normally a bail is provided...

Page 23: ...ify TX and RX connector before making cable connection The following figure illustrates a connection example between two fiber ports Make sure the Rx to Tx connection rule is followed on the both ends of the fiber cable Network Cables Multimode MMF 50 125 62 5 125 Single mode SMF 9 125 3 3 Making Console Connection ...

Page 24: ...ctor designed for the console port is RJ 45 Pin Assignments Pin RS 232 signals IN OUT 1 2 7 8 NC 3 RxD IN 6 TxD OUT 4 5 GND Baud Rate information Baud rate 115200 Data bits 8 Parity None Stop bit 1 Flow control None ...

Page 25: ...ith diagnostic error or system Green ON Initialization completed with no error Port1 Port 8 SPEED_LED Port speed status Green ON Speed is 1000Mbps Yellow ON Speed is 10Mbps or 100Mbps LINK_LED Port link status Green ON Port link is established No traffic BLINK Port link is up and there is traffic OFF Port link is down Port 9 Port 12 SPEED_LED Port speed link status Green ON A 1000Mbps link is esta...

Page 26: ... the switch 192 168 0 2 255 255 255 0 The switch uses local authentication instead of RADIUS authentication with factory defaults Fixed Username admin Default password No password is required with factory default However the password is used for local authentication in accessing to the switch via console telnet and Http web based interface For security reason it is recommended to change the defaul...

Page 27: ...ete user_name Refer to Operation manual for telnet and console management 4 3 Configuring IP Address via Web Interface Start Web Browser Start your browser software and enter the default IP address of the switch unit to which you want to connect The IP address is used as URL for the browser software to search the device URL http 192 168 0 2 Login to Switch Unit When browser software connects to th...

Page 28: ... 28 No password is required Click OK to login into the switch Web Page after a Successful Login Select Configuration System IP to configure IP address ...

Page 29: ... enabled DUT will relay DNS requests to the current configured DNS server on DUT and reply as a DNS resolver to the client device on the network Save Click to save the changes Reset Click to undo any changes made locally and revert to previously saved values Renew Click to renew DHCP This button is only available if DHCP is enabled 4 4 Reference Manuals for Web Console Telnet Management The follow...

Page 30: ...IPv6 Destination ipv6_addr SNMP Trap Authentication Failure enable disable SNMP Trap Link up enable disable SNMP Trap Inform Mode enable disable SNMP Trap Inform Timeout timeout SNMP Trap Inform Retry Times retries SNMP Trap Probe Security Engine ID enable disable SNMP Trap Security Engine ID engineid SNMP Trap Security Name security_name SNMP Engine ID engineid SNMP Community Add community ip_add...

Page 31: ...nities that permit to access to SNMPv3 agent USM User based Security Model user table for SNMPv3 VACM View based Access Control Model Viewer table for SNMPv3 Group table for SNMPv3 Accesses group table for SNMPv3 4 6 SNMP MIBs The switch provides the following SNMP MIBs RFC 1213 MIB II RFC 2674 QBridge MIB VLAN MIB RFC 2819 RMON Group 1 2 3 9 RFC 2863 Interface Group IF MIB RFC 3411 SNMP Managemen...

Page 32: ...P Firmware update over SNMP Private OPA function MIB OPA configuration for the SFP ports Private ALS function MIB ALS configuration for the SFP ports One product MIB file is also available in the product CD for SNMP manager software 4 6 1 SNMP Traps In addition to the SNMP standard traps the device is equipped with private OPA alarm traps The traps are Alarm trap Port TX power lower than the minim...

Page 33: ...ion can support more than one ring connection within a switch It is also able to work with RSTP support concurrently in the switch Some basic information is Supports up to six rings in one switch Supports up to 100 member switches in one ring Provides fast response time than RSTP protocol Works with RSTP protocol concurrently within one switch The following figure illustrates a configuration that ...

Page 34: ...the same time 5 2 Redundant Ring Applications with industrial standard RSTP protocol It also can be done to support a ring connection using industrial standard RSTP function and establish a backup path In case that any link failure occurs the backup path can link up immediately to recover the network operation ...

Reviews: