Installation and operating manual

KT-Elektronik

Warranty

We permanently enhance our products, therefore we reserve the right to make changes to our 
products at any time and without prior notice.
We take no responsibility for the accuracy or completeness of this manual. No liability can be accepted 
for the use of our products for a buyer specific purpose. Buyer claims, especially claims for damages 
including lost profits or other financial losses are excluded. This does not apply if the damage caused 
by intent or gross negligence. In case of negligent violations of major contractual obligations, our 
liability is limited to the foreseeable damage 

Security advices

Only qualified personnel that is familiar with installation and commissioning of this product is 
allowed to mount the device and put it into operation. Appropriate shipping and storage are 
assumed.

The product is designated for use in heavy current equipment. Installation and maintenance 
have to be performed according to the corresponding safety regulations.

Contents

Installation......................................................................................................................................................................................

3

Mounting................................................................................................................................................................................

3

Electrial connecting................................................................................................................................................................

3

Control system communication.....................................................................................................................................................

4

Baud rate...............................................................................................................................................................................

4

Addressing.............................................................................................................................................................................

4

Addressing at delivery...........................................................................................................................................................

4

Addressing by slave device TROVIS 5573, SOL3-1, SOL3-7 and WPR3............................................................................

4

Address change in stand-alone operation ............................................................................................................................

4

Connection to the control system BMS.........................................................................................................................................

4

Connection to the slave device.....................................................................................................................................................

4

Connection to MBus......................................................................................................................................................................

4

Display and operation ...................................................................................................................................................................

5

LED status ............................................................................................................................................................................

5

Updating the firmware...................................................................................................................................................................

6

Configuration using 5012Config....................................................................................................................................................

6

Technical specification...................................................................................................................................................................

7

2

EB_11997_ModBus-MBus-Gateway_EN001

Summary of Contents for ModBus-MBus-Gateway

Page 1: ...ModBus MBus Gateway Installation and operating manual Firmware version 1 0x May 2011...

Page 2: ...ices Only qualified personnel that is familiar with installation and commissioning of this product is allowed to mount the device and put it into operation Appropriate shipping and storage are assumed...

Page 3: ...ead cyclically via MBus from meters and stored in an internal memory of the ModBus MBus Gateway A control system can read the last temporarily stored meter data via Modbus from the ModBus MBus Gateway...

Page 4: ...s change in stand alone operation Through two holding registers may be adjusted an 8 bit station address or a 16 bit address of the ModBus MBus Gateway The last address written determines the addressi...

Page 5: ...he operation of slave device To indicate operating state and function are 10 luminous dots LEDs are located on the front panel of the ModBus MBus Gateway LED status An LED lights up when the value spe...

Page 6: ...ing the software BootManager In this case the ModBus MBus Gateway provides a transparent connection between BootManager and slave device Configuration using 5012Config For the configuration of the con...

Page 7: ...g voltage 85 to 250 V 48 to 62 Hz max 1 8 W Ambient temperature 0 to 40 C operation 10 C to 60 C storage and transport Type of protection IP 20 according to IEC 529 Protection class II according to VD...

Page 8: ...ronik GmbH Berlinickestrasse 11 12165 Berlin Germany Telephone 030 79 08 05 0 Telefax 030 79 08 05 20 E mail info kt elektronik de Internet http www kt elektronik de EB_11997_ModBus MBus Gateway_EN001...