background image

04

7.

INSTALLATION REQUIREMENTS: 

For safe effective installation of the Reusable Concrete Anchor, make sure to observe the following 

requirements:

Concrete:

 A compressive strength of 3000 p.s.i. (20.7 MPa) is must for the concrete to secure the anchor. Do not use the Reusable 

Concrete Anchor in lightweight concrete, hollow block, grout, stone, wood, steel or any other substrate. The concrete base material must 
be at least 5 inches (12.7 cm) thick.

Mounting Hole Location:

 The thickness and width of the concrete is considered to analyze the allowable distance for mounting the 

Reusable Concrete Anchor from an edge or corner. Mounting hole location requirements are as follows:

Ÿ

Ÿ

Concrete Thickness

12 in (30.5 cm)

10 in (25.4 cm)

8 in (20.3 cm)

5 in (12.7 cm)

12 in (30.5 cm)

16 in (40.6 cm)

20 in (50.8 cm)

24 in (61 cm)

6 in (15.3 cm)

8 in (20.3 cm)

10 in (25.4 cm)

12 in (30.5 cm)

Minimum Mounting Distance from Edge/Corner

Concrete Width

Note:

 Drill bits for drilling mounting holes must conform to ISO 5468 addressing carbide-tipped masonry drills 

and blanks for carbide-tipped masonry drills.

8.

 ANCHORAGE STRENGTH:

 Ensure that the structure on to which the anchor is fitted is strong enough to withstand a load of 

20kN.

9.

LIMITATION:

Ÿ

It should be the personal property of its user.

Ÿ

It should not be used in highly acid or basic environments.

Ÿ

The equipment shall not be used out side its limitation, or for any purpose other than that for which it is intended.

Ÿ

The anchor has been tested to EN 795 : 2012 Type B and is appropriate for maximum of single person use with energy 
absorber as per EN 355:2002 that is rated to user mass of up to 140kg including tools.

Ÿ

It is essential for the safety of user that if the product is resold outside the original country of destination, the reseller 

shall provide instruction for use, for maintenance, for periodic examination and for repair in the language of the country 
in which product is to be used.

Ÿ

It is advisable to use the dorsal attachment D-Ring of the harness for connection.

Ÿ

A full body harness is the only acceptable body holding device that can be used in fall arrest system.

Ÿ

Following conditions may be hazardous & may affect the performance of Anchor -

Ÿ

Extreme temperature.

Ÿ

Trailing or looping of Lanyards over sharp edges.

Ÿ

Extreme acidic or basic environments.

Ÿ

Abrasive or sharp edge structures which can damage the equipment.

Ÿ

Chemical Reagents.

Ÿ

Climatic exposure.

Ÿ

When the equipment gets wet, either from being in use or when due to cleaning, it should be allowed to dry by itself and 
be kept away from open fire or any other source of heat.

Ÿ

When Anchor device is used as part of a fall arrest system, the user shall be equipped with a means of limiting the 
maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 6 kN.

Ÿ

Any dangers that may arise by the use of combinations of items of equipment in which the safe function of any one item 
is affected by or interferes with the safe function of another.

Ÿ

Ensure that the harness used confirms to EN 361 and the Karabiner is connected to attachment elements of the
 harness; also ensure that harness has an attachment located appropriately to the fall arrester.

Summary of Contents for AFA930301

Page 1: ...THESE INSTRUCTIONS APPLY TO THE FOLLOWING MODEL EDGE REUSABLE CONCRETE ANCHOR USER INSTRUCTION MANUAL AFA930301 EN 795 2012 TYPE B EN 80079 36 2016 EN 80079 37 2016...

Page 2: ...sion evident after 48 hours of salt spray testing PASS 3 APPLICATION ThisAnchorisdesignedforfasteningintoapre definedholeofdia 20mm throughadrillingdepthof Minimum Theanchorageeyeisusedasananchoragepo...

Page 3: ...rigger whileplacingtheanchor Alsountilthetriggerandspringfullycompresses squeeze thefingersandthumbtogether Tolocktheanchor releasethetriggerafterinserting itintheholeatleast3 76mm deep SQUEEZE THE TR...

Page 4: ...orage Reusable Concrete Anchorage Connector Back up Fall Arrest System Reusable Concrete Anchorage Connector Suspension Line Seat Board Personnel Riding With the help of trigger grip one can get fast...

Page 5: ...ted to EN 795 2012 Type B and is appropriate for maximum of single person use with energy absorberasperEN355 2002thatisratedtousermassofupto140kgincludingtools It is essential for the safety of user t...

Page 6: ...ots gloves helmet and ear protection In this case before carrying out the risk related activity consult your supplier to ensurethatallyourprotectiveproductsarecompatibleandsuitableforyourapplication 1...

Page 7: ...the manufacturer iii Type or product code iv Minimum Breaking Strength v UID for traceability of Product vi Norm Reference vii Read The Instruction Before Use viii For single user only ix Atex markin...

Page 8: ...xposure UVexposure abrasions cuts violentimpacts baduseormaintenance DISCLAIMER Priortouse theendusermustreadandunderstandthemanufacturer sinstructionssuppliedwiththisproduct at the time of shipment a...