background image

02

A diameter hole of 0.75” (20mm) with 
minimum deepness of 3.5” (89mm) is 
to be drilled ensuring it to be straight 
and perpendicular to the surface. The 
drilled  hole  must  have  a  uniform 
diameter with no trace of peaks and 
valleys  on  the  inner  wall.  Clean  the 
drilled  hole  by  blowing  compressed 
air.

Now the eye of the anchor can be 
used as anchorage point. Connect 
the lanyard with the anchor.

Now the anchor is ready to use.

Put your thumb inside the anchor loop and the first two fingers around the trigger 
while placing the anchor. Also until the trigger and spring fully compresses, squeeze 
the fingers and thumb together. To lock the anchor, release the trigger after inserting 
it in the hole at least 3” (76mm) deep.

SQUEEZE THE TRIGGER 

RELEASE THE TRIGGER 

6.

INSTRUCTIONS FOR USAGE : AFA930301

The concrete Anchor (AFA930301) may be attached to the structure by pulling on the spring loaded trigger component.

Spoon Orientation

* Best practice for spoon orientation when 

0

  loaded 90  to hole.

Load

Best

Load

OK

See Spoon Orientation

PROPER LAODING

See Spoon Orientation

Good

Best

Good

0

0

0

90

0

90

HOLE DRILLING REQUIREMENT CHART

(A)” Minimum distance from edge/corner

(B)” Concrete thickness

(B)”

6” (15.3 cm)

12” (30.5 cm)

12” (30.5 cm)

5” (12.7 cm)

Summary of Contents for AFA930301

Page 1: ...THESE INSTRUCTIONS APPLY TO THE FOLLOWING MODEL EDGE REUSABLE CONCRETE ANCHOR USER INSTRUCTION MANUAL AFA930301 EN 795 2012 TYPE B EN 80079 36 2016 EN 80079 37 2016...

Page 2: ...sion evident after 48 hours of salt spray testing PASS 3 APPLICATION ThisAnchorisdesignedforfasteningintoapre definedholeofdia 20mm throughadrillingdepthof Minimum Theanchorageeyeisusedasananchoragepo...

Page 3: ...rigger whileplacingtheanchor Alsountilthetriggerandspringfullycompresses squeeze thefingersandthumbtogether Tolocktheanchor releasethetriggerafterinserting itintheholeatleast3 76mm deep SQUEEZE THE TR...

Page 4: ...orage Reusable Concrete Anchorage Connector Back up Fall Arrest System Reusable Concrete Anchorage Connector Suspension Line Seat Board Personnel Riding With the help of trigger grip one can get fast...

Page 5: ...ted to EN 795 2012 Type B and is appropriate for maximum of single person use with energy absorberasperEN355 2002thatisratedtousermassofupto140kgincludingtools It is essential for the safety of user t...

Page 6: ...ots gloves helmet and ear protection In this case before carrying out the risk related activity consult your supplier to ensurethatallyourprotectiveproductsarecompatibleandsuitableforyourapplication 1...

Page 7: ...the manufacturer iii Type or product code iv Minimum Breaking Strength v UID for traceability of Product vi Norm Reference vii Read The Instruction Before Use viii For single user only ix Atex markin...

Page 8: ...xposure UVexposure abrasions cuts violentimpacts baduseormaintenance DISCLAIMER Priortouse theendusermustreadandunderstandthemanufacturer sinstructionssuppliedwiththisproduct at the time of shipment a...