1 - Detection Area

Detection area can be reduced by selecting

the combination on the Dip Switches,
following the guide as shown here.

2 - Hold Time

Hold time means the time period you would
like the light to remiain 'on' once no movement
is detected.

3 - Daylight Sensor

The daylight sensor can be set to bring the

light 'on' at specific daylight levels. To have

the sensor function in daylight set the Dip
Switches to Disable.

KSR Lighting Ltd, Unit E Hazleton Interchange, Lakesmere Road, Horndean, Hampshire, PO8 9JU

Installation Sheet

KSRSF332

Read these instructions before commencing installation. Please give these instructions to the
owner/occupier after installation to retain for future reference/maintainence.

KSR Microwave On/Off Sensor Set Up Guide

Issue

Cause

Solution

The load will

not illuminate

Incorrect daylight threshold
setting selected

Adjust setting and

retest

Load has failed
(driver or LED array)

Replace load

No mains power detected

Switch on power

The load is

permanently
illuminated

Continuous movement in
the detection area

The lamp (containing sensor)

is installed in an area too close

to reflective surface, i.e Metal,
Glass or Concrete walls.

Check detection area setting

Make sure installation area suitable

with at least 30cm space

between lamp and surrounding
reflective surfaces
Reduce Sensitivity (detection area)

1.

2.

The load will not

illuminate despite
movement

Speed of moving object is not
in the range of 0.5-3m/s or the
detection radius is too small

Check Detection area setting

This Microwave sensor is a motion activated switch, it will turn the light on when

movement is detected, then hold the light on for the determined amount of

time, after which the light will turn off.

Using the Dip Switches on the sensor, set it up to your preferred Detection area,
Hold Time & Daylight level.

Microwave sensors will detect movement through certain materials, if this occurs
reduce the detection area until any nuisance triggering stops.

Max Load - 400W (Inductive)(LEDs)
Max Load - 800W (Resistive)

Troubleshooting

The Sensor is designed for installation heights of 3-6m

Recommended Installation heights

For Wall mounting the height is 1.5m

For Ceiling mounting the height is 3m

Detection Zone Max. (D x H): 12m x 6m

Detection Angle: 150° (wall Installation)

   360° (ceiling Installation)

Navara SF Select

6m

2-6m

6m

Diameter (D)

Height (H)

Summary of Contents for KSRSF333

Page 1: ...cated in Fig 2 and lift the hinged tray to gain access to the wiring terminals Pass intended supply wires through grommet Ensure the fixing surface is flat and even Fix base to the wall ceiling or besa box using adequate fixings with regard to the type of surface Ensure incoming cables are protected Terminate wiring as per Fig 3 please note an Earth terminal is only supplied to aid the continuatio...

Page 2: ... is installed in an area too close to reflective surface i e Metal Glass or Concrete walls Check detection area setting Make sure installation area suitable with at least 30cm space between lamp and surrounding reflective surfaces Reduce Sensitivity detection area 1 2 The load will not illuminate despite movement Speed of moving object is not in the range of 0 5 3m s or the detection radius is too...

Page 3: ...evice should be checked to ensure that it shows the unswitched supply has been restored The charging arrangements should be checked for proper functioning 3 The date of the test and its results shall be recorded in the system logbook A copy of this report must accompany any emergency luminaire returned to KSR Lighting for any reason Battery Maintenance Removal and Replacement Procedure For battery...

Page 4: ...ite Address Test Conducted By Date of Test Completion Comments Actions Emergency Lighting Periodic Test Schedule All emergency lighting should be installed and tested in accordance to EN5266 1 2011 This test schedule should remain onsite and be accessible to the relevant authorities on request ...

Reviews: