background image

Ceiling mounted

Wall mounted

300mm

84mm

Drg No. KSRSF333-IS-E

KSR Lighting Ltd, Unit E Hazleton Interchange, Lakesmere Road, Horndean, Hampshire, PO8 9JU

26.04.2022MAC

Installation Sheet

KSRSF333

Read these instructions before commencing installation. Please give these instructions to the owner/occupier after
installation to retain for future reference/maintainence.

Navara SF Select

 Available Rims: Various please visit www.ksrlighting.com for options

Multi Wattage Triple CCT Bulkhead

IP65  IK10

240V~50Hz 10W/14W/20W

These fittings are Class II and do not need an Earth, but Earth provision is provided.

Important Information

It is recommended that these luminaires are installed and fitted by a qualified electrician ensuring the installation complies

with current IEE wiring regulations & local building control. These products are designed for connection to a 240V~50Hz
supply.
Any faulty, broken or damaged luminaires should be replaced immediately.

KSR will not accept responsibility for any claims arising from a poor installation.
Please Note: The limited warranty shall be deemed null and void in the following circumstances: Failure by the installer,

end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse
temperature (normal operating ambient temperature -10

°C - +30°C), humidity conditions, fluctuations in the electrical

system or physical abuse as well as failure related to workmanship in the installation of the products or parts.

Important User Advice

Always switch off mains supply before servicing.

Do not use Megger or similar high voltage instruments. Due to the fact this luminaire contains electronic components that
maybe damaged by high test voltages, they must be disconnected from the circuit before testing.

To prevent damage to the driver, do not mix with conventional magnetic ballasts on the same electrical circuit.
At the end of life the luminaire is classed as WEEE under directive 2014/30/EU and should be disposed of in accordance
with local legislation.

Installation Procedure

Isolate mains supply before installation.
Unscrew and retain the four screws and remove the diffuser.
Loosen the single LED tray screw as indicated in Fig.2 and lift the hinged tray to gain access to the wiring terminals.
Pass intended supply wires through grommet.
Ensure the fixing surface is flat and even.
Fix base to the wall, ceiling or besa box using adequate fixings with regard to the type of surface.
Ensure incoming cables are protected.

Terminate wiring as per Fig. 3, please note an Earth terminal is only supplied to aid the continuation of the Earth circuit.

Please ensure battery is connected, this battery compartment can be accessed as shown overleaf.
Select LED colour and wattage required using the switches on the LED driver Note: Never change the LED colour or

wattage with the luminaire powered on as this can damage the luminaire. Fig. 4.

Set Microwave to desired settings, for set up please refer to page overleaf.

Remove the battery cover and connect the emergency battery, replace battery cover (see overleaf).

Re-secure the LED tray.
Make sure the seal is in place in the diffuser and undamaged.
Replace the diffuser re-secure using the four retained screws.

Turn on the mains supply and test luminaire. If using an optional rim clip the rim over the fitting.

This fitting requires a 24 Hour initial charge period prior to any emergency testing, please see
overleaf for testing routine, write on the battery label in permanent ink the date of commissioning.
All results must be recorded and left with the end user.

The battery has a design life of at least 4 years but should be replaced if the duration of
operation is less than 3 hours after a 24hr charge time with no interrupted supply.

*Please note: Depending on the amount of fittings on a circuit you may have to upgrade the breaker
to a 'C' or 'D' type to avoid nuisance tripping.

Fig. 1

Fig. 2

Gear Tray Retaining Screw

3000K

4000K

6000K

20W

14W

10W

Model: KSRSF330/331/332/333

  KSRSF400/401/402/403

Input:220~240Vac 50/60Hz

Output:80-120VDC 175mA(Max)

Prated:20W Max

Tc

Ta:40

°C

TC:85

°C

V+

G-

W-

E+

Made in China

G-

G+

N

L

Fig. 4

Wattage

LED Colour

KSR Lighting Aftersales: 023 92 674343
E-mail: [email protected]

Lamp Details

Lamp: LED

Wattage: 10W, 14W, 20W

Colour: 3000K, 4000K and 6000K CCT
CRI: Ra>84

This product contains a light source of energy efficiency class F

Lumen output

CCT

10W

14W

20W

3000K

4000K

1145lm

1261lm

1658lm

1457lm

2126lm

1819lm

6000K

1212lm

1559lm

1947lm

Fig. 3

Mains Supply

Permanent Live - Black

PL

Switch Live - Brown

Neutral - Blue

SL

N

X

Earth Continuation Only

Summary of Contents for KSRSF333

Page 1: ...cated in Fig 2 and lift the hinged tray to gain access to the wiring terminals Pass intended supply wires through grommet Ensure the fixing surface is flat and even Fix base to the wall ceiling or besa box using adequate fixings with regard to the type of surface Ensure incoming cables are protected Terminate wiring as per Fig 3 please note an Earth terminal is only supplied to aid the continuatio...

Page 2: ... is installed in an area too close to reflective surface i e Metal Glass or Concrete walls Check detection area setting Make sure installation area suitable with at least 30cm space between lamp and surrounding reflective surfaces Reduce Sensitivity detection area 1 2 The load will not illuminate despite movement Speed of moving object is not in the range of 0 5 3m s or the detection radius is too...

Page 3: ...evice should be checked to ensure that it shows the unswitched supply has been restored The charging arrangements should be checked for proper functioning 3 The date of the test and its results shall be recorded in the system logbook A copy of this report must accompany any emergency luminaire returned to KSR Lighting for any reason Battery Maintenance Removal and Replacement Procedure For battery...

Page 4: ...ite Address Test Conducted By Date of Test Completion Comments Actions Emergency Lighting Periodic Test Schedule All emergency lighting should be installed and tested in accordance to EN5266 1 2011 This test schedule should remain onsite and be accessible to the relevant authorities on request ...

Reviews: