- 25 -
7.0 Main Switch
The stoker is provided with a main switch mounted on the boiler side. The main switch should be locked
when working on the plant.
8.0 Starting Up The Stoker.
This is the simplest way to start up the stoker:
The stoker is ignited by pressing turning the main switch to position 1.
An appropriate amount of fuel is conveyed into the burner, by pressing SCREW START.
Turn off the stoker, preferably ignite without the combustion air fan running.
Pour a little ignition liquid (grill igniters) onto the pellets, and set fire.
Once the pellets have caught fire, re-start the stoker (The yellow main switch)
Press STOP SCREW, and let it stay inactivated until the combustion is well established, then press
START SCREW, and the screw feedings are from now on decided by the control impulses.
Always make sure that the circulation pump is switched off when you start the stoker, and do not switch
on the pump again until the control has moved from the starting-up mode and into Step 3. In this way,
the boiler will reach the proper temperature sooner and the control will not de-clunch due to
UNDERTEMP.
Biofuel and
ignition liquid.