KSI Filtertechnik GmbH
| www.ksi.eu · [email protected]
25
The filters are carefully tested in the factory and are handed over to the
shipping contractor in perfect condition. However, please inspect the goods
for any visible damage and, if any such damage is observed, please enter a
comment to this effect on the reception slip. The manufacturer is not respon-
sible for any damage in transit (as a general principle, all deliveries are „ex
works“).
Performance data:
The filter housings may only be installed under the following operating
conditions:
Maximum pressure: Rp
≤
2
½
“ = 16 bar g ; Rp > 2
½
“ = 12 bar g
Minimum pressure for all housings: 1,5 bar g
Maximum operating temperature: 80 °C
Minimum operating temperature: 1,5 °C
Deviation in vacuum filters:
Maximum operating vacuum: -917 mbar g
Maximum operating temperature filter elements: 80 °C
6
Installation & Commissioning
Position:
The housing must be installed vertically. When installing, the specified flow
direction must be observed (indicated by arrow). Any possibility of transmit-
ting of vibration from piping networks to the filter housing must be elimina-
ted. Make sure that there is sufficient space underneath the bottom of the
housing to replace the filter elements. Please also comply with the maxi-
mum temperature specifications. Ensure sufficient clearance to the wall, so
that e.g. you have space to insert a belt-type filter wrench.