11
EN
FUNCTIONS
POWERING UP
The device programmation and the panel configuration are made by
basis
SW. The siren manages the
outputs as:
• If
imago
is powered with the non-rechargeable battery (
KSI7207580.000
) the outputs will be managed
as below, regardless the programmed configuration
• Alarm output: monastable with the same ON time as programmed on the Panel (
default: 3 min.
)
• Power LED output: monostable with fixed 20 sec. ON time
• Aux LED output: monostable with fixed 20 sec. ON time; this function is designed to save battery
• If
imago
wireless is powered with external 12Vdc supply and rechargeable acid lead battery, it will
manage the outputs as programmed
During the programming phase, every time the
imago
sends a tamper signal to the panel and it is
acknowledged the red LED on the wireless PCN module will blink.
The procedure to power up the imago requires to respect at least one of the following steps:
• Connect the batteries to their connector
13
and place it on its base
10
as shown in figure
• Connect the power supply poles + and - (
12Vcc
) to their clamps
14
and the acid lead backup
battery to the respective cables with faston
21
after been placed on its base
10
as shown in figure
If wiring is correct,
imago
will show a single flash by the power LED and a short BEEP by the buzzer.
OR