Ksenia imago wls 96 Installation Manual Download Page 5

code R30019.101en                                                                                                                                                                           www.kseniasecurity.com
ed.04/2020

Connect the power supply poles + and - (12Vcc) to their clamps (n.14) and the acid lead backup battery 
to the respective cables with faston (n.21) after been placed on its base (n.10) as shown in next figure

If wiring is correct, imago will show a single flash by the power LED and a short BEEP by the buzzer.

ENROLLING

To enrol imago wireless on the system, please follow the procedure here below:
1. On the ergo keypad, browse the programming menu till the ‘Enroll’ mode
2. Move the front anti-opening switch (open/close the cover of the imago)
3. On the ergo keypad, confirm the S.N. of the device.
If enrolling is successfully made, the red LED on RF PCB module will turns on as confirmation.
For any additional information, please see the lares 4.0 Programming Manual.

QUANTITY DATA

FUNCTIONS

The device programming and the panel configuration are made by basis SW. 
The siren manages the outputs as:

If imago is powered with the non-rechargeable battery (KSI7207580.000) the outputs will be managed 
as below, regardless the programmed configuration:

• Alarm output: monostable with the same ON time as programmed on the Panel (default: 3 min.)
• Power LED output: monostable with fixed 20 sec. ON time
• Aux LED output: monostable with fixed 20 sec. ON time; this function is designed to save battery

If imago wireless is powered with external 12Vdc supply and rechargeable acid lead battery, it will 

manage the outputs as programmed.

During the programming phase, every time the imago sends a tamper signal to the panel and it is 
acknowledged the red LED on the wireless PCN module will blink.

lares 4.0 models

wls 96

16

40

40 wls

140 wls

644 wls

Maximum number of imago 
wireless siren

3

3

3

3

5

5