TECHNICAL DATA
•
Modern Design with original and convenient rotating opening
•
Solid PC housing (minimum thickness 3 mm.) with anti-UV pigment
•
Front available in different colors
•
Transparent base available in different colors: orange, red and blue
•
Strong metallic zinc-plated under-cover (anti-smashing)
•
High acoustic power piezoelectric Buzzer (>100dBA @ 1m)
•
Protective and insulating treatment of the PCB (conformal coating)
•
Power Supply: 9V(min.) - 13.8V max (not included)
•
Reloadable Backup battery: 6Vcc – 1.2Ah (not included)
•
Un-reloadable Main battery: 7.5Vcc – 8Ah non-reloadable (not included)
•
Operative temperature range: -10° +55°C 95% humidity
•
Protection class: IP44
•
Dimensions: 195 x 330 x 60 mm
•
Weight (without battery): Kg 1.200
•
Wireless bi-directional communication; 868MHz frequency
•
RF Range: 300 m. in open air
•
Supervision for wireless diagnostic (programmable)
•
Temperature sensor (switchable)
•
Temperature thresholds managing (programmable)
•
Management of the maximum duration of the alarm (programmable)
•
Alarm output configurable as Bistable or Monostable
•
Power LED output configurable as Bistable or Monostable
•
Auxiliary LED output configurable as Bistable or Monostable
•
Acoustic signals of RF level OK
Using imago wireless powered with main battery (7.5V - 8Ah), the lifetime expectancy is up to 3 years in the
following conditions:
•
4 daily cycles of turning on the auxiliary LEDs;
•
Supervision interval programmed at 5 minutes;
•
1 monthly alarm cycle of 5 minutes each and 4 test alarm cycles;
Notes:
1. At temperatures below -5° C the siren may give a “wrong battery” message.
2. Working below -5°C significantly reduces battery life.
3. Replace the battery pack using only the model KSI7207580.000.
4.
Warning!
Risk of explosion if the battery is replaced by an incorrect type or if handled incorrectly –
do not recharge, open or throw on a fire.
5. Dispose of used batteries according to the instructions.