4 Description of the Pump (Set)
22 of 80
Vitacast / Vitacast Bloc
Drive
Standard design:
▪
KSB surface-cooled IEC three-phase current squirrel-cage motor
▪
50 Hz winding, 220 - 240 V / 380 - 420 V ≤ 2.20 kW
▪
50 Hz winding, 380 - 420 V / 660 - 725 V ≥ 3.00 kW
▪
60 Hz winding, 440 - 480 V ≤ 2.60 kW
▪
60 Hz winding, 440 - 480 V ≥ 3.60 kW
▪
Type of construction IM V1 ≤ 4.00 kW
▪
Type of construction IM V15 ≥ 5.50 kW
▪
Enclosure IP55
▪
Duty cycle: continuous duty S1
▪
Thermal class F with temperature sensor, 3 PTC thermistors
Explosion-proof version:
▪
KSB surface-cooled IEC three-phase current squirrel-cage motor
▪
50 Hz winding, 220 - 240 V / 380 - 420 V ≤ 1.85 kW
▪
50 Hz winding, 380 - 420 V / 660 - 725 V ≥ 2.50 kW
▪
Type of construction IM V1 ≤ 3.30 kW
▪
Type of construction IM V15 ≥ 4.60 kW
▪
Enclosure IP55 or IP54
▪
Duty cycle: continuous duty S1
▪
Type of protection EEx e II
▪
Temperature class T3
Automation
Automation options:
▪
PumpDrive
▪
PumpMeter
Connections
▪
Axial suction nozzle, tangential discharge nozzle
▪
Adjustable through 360°
Types of connection:
▪
Threaded connection to DIN 11851 (hygienic pipe union)
▪
Threaded connection to DIN 11853
▪
Threaded connection to DIN 11864-1-GS-A
▪
Threaded connection to SMS standard
▪
Threaded connection to ISO 2853 (IDF)
▪
Threaded connection to RJT standard
▪
Clamped connection to DIN 32676-C (Tri-Clamp/Tri-Clover fitting)
▪
Clamped connection to DIN 11864-3-NKS-A
▪
Clamped connection to DIN 32676-A
▪
Clamped connection to ISO 2852
▪
Flange to EN 1092-1
▪
Flange to DIN 11864-2-NF-A
▪
Flange to ANSI B16.5 Class 150
▪
APV flange
▪
Varivent flange
▪
Other connection types on request