3
Transport/Temporary Storage/Disposal
3.1
Transport
DANGER
The pump set could slip out of the suspension arrangement.
Danger to life from falling parts!
▷
Always transport the pump set in horizontal position.
▷
Never attach the suspension arrangement to the free shaft end or the motor
eyebolt of the pump set.
▷
Refer to the weights given in the general arrangement drawing.
▷
Observe the local health and safety regulations.
▷
Use suitable, permitted lifting tackle, e.g. self-tightening lifting tongs.
To transport the pump set suspend it from the lifting tackle as shown below.
Fig. 1: Transporting the pump set
3.2
Storage and preservation
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken for pump (set) storage.
CAUTION
Damage during storage by humidity, dirt, or vermin
Corrosion/contamination of the pump (set)!
▷
For outdoor storage cover the packed or unpacked pump (set) and accessories
with waterproof material.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage to the pump set!
▷
Only remove caps/covers from the openings of the pump set at the time of
installation.
Store the pump (set) in a dry, protected room where the atmospheric humidity is as
constant as possible.
Rotate the shaft by hand once a month, e.g. via the motor fan.
If properly stored indoors, the pump set is protected for a maximum of 12 months.
For storing a pump (set) which has already been operated, observe the instructions
given in this manual. (
3 Transport/Temporary Storage/Disposal
10 of 36
Trialine / Trialine Z