Dimensions of the display unit
Scope of supply
▪
Display unit fitted
▪
Sensors fitted with adapter
Fluids handled
Overview of fluids handled
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Alum, acid-free
3
80
Diesel oil
–
80
Alkaline solution, bottle rinsing, max. 2% sodium
hydroxide
–
40
Diesel oil, fuel oil EL
–
60
Alcohol
–
–
Lubricating oil, turbine oil, does not apply to
SF-D oils (hardly flammable)
–
80
Aluminium sulphate, acid-free
5
60
Heating oil
–
80
Ammonium bicarbonate
10
40
Water-oil emulsion (95%, 5%), free of solids
–
80
Ammonium sulphate
20
60
Phosphate sludge
…10
60
Anolyte (dialyte) with acetic acid or formic acid,
free of solids
–
30
Phosphoric acid
5
20
Accelerator (as preparation)
–
–
Propanol
–
80
Drilling/grinding emulsion
–
60
Cleaning agents
–
–
Spirits (40% ethanol)
–
60
Juice (fruit and sugar juice)
–
60
Service water
–
60
Nitric acid
15-20
80
Brewery applications
–
–
Silicate-free, alkaline degreasing or cleaning
solution containing solid particles
0.3-5
80
Beer mash
–
100 Fuel
–
–
Beer wort
–
100 Trisodium phosphate
4
80
Brewing water
–
60
Water
–
–
Ice water (brewery)
–
60
Deionised water (fully desalinated)
–
140
Vapour condensate (brewery)
–
140 Dealkalised water
–
120
Butanol
–
60
Decarbonised water
–
120
Calcium acetate, acid-free
10
60
Fire-fighting water
4)
–
60
Calcium nitrate, acid-free
10
60
River water
–
60
Diethylene glycol
–
100 Heating water
5)
–
140
4)
General criteria for results of water analysis: pH value
≥
7; chloride content (Cl)
≤
250 mg/kg. Chlorine (Cl 2)
≤
0.6 mg/kg
5)
Treatment to VdTÜV 1466; additional requirement: O2
≤
0.02 mg/l
Monitoring
Intelligent Pressure Sensor
PumpMeter
5