background image

Monitoring

Intelligent Pressure Sensor

PumpMeter

PumpMeter

Product description

The PumpMeter device is an intelligent pressure sensor for
pumps, with local output of measured values and operating
data.

The device consists of two pressure sensors and a display unit.
It records the load profile of the pump in order to indicate any
potential for optimising energy efficiency and availability.

PumpMeter is supplied completely assembled and
parameterised for the corresponding pump. It is ready for
operation as soon as the M12 plug connector is plugged in.

Main applications

Industry:

Refrigeration/distribution

Heat generation/distribution

Water conditioning

Cooling lubricant distribution

Water extraction

Service water supply

Water:

Water extraction/withdrawal

Water treatment/conditioning

Water distribution/transport

Building Services:

Air-conditioning systems

Heat generation/distribution

Water supply systems

Technical data

Technical data of the display unit

Characteristics

Value

Power supply

24V DC ± 15%

Power input

150 mA

Analog signal output

4-20 mA, 3-core

Digital connection

RS485, Modbus RTU
(Slave)

Enclosure

IP 65

1)

Service interface

RS232

Bearing temperature

-30 °C to 80 °C

Operating temperature

-10 °C to 60 °C

Technical data of the sensors

Characteristics

Value

Signal

4-20 mA

Gauge pressure

40 bar max.

Enclosure

IP 67

1)

Burst pressure

80 bar max.

Fluid temperature

-30 °C to 140 °C

Installation torque

10 Nm

Ambient temperature

-10 °C to 60 °C

Materials

Overview of materials

Wetted components

Material

Pressure sensor measuring unit

1.4542

Pressure sensor process connection

1.4301

Adapter for fitting a sensor

2)

1.0037 or 1.4571

Joint ring

Centellen®

Product benefits

Transparent pump operation
Local output of the relevant operating data, especially the
operating point of the pump.

Identifies energy saving potentials
by recording and analysing the load profile and displaying
the energy efficiency icon (EFF), if applicable.

Saves time and money
The sensors are fitted to the pump at the factory, unlike
conventional instruments used in systems.

Helps increase pump availability
by recognising and avoiding operation outside of the
intended operating range.

Functions

Pressure transmitter function
The discharge pressure or differential pressure of the pump are
transmitted as a 4-20 mA signal. Connection via the RS485
serial interface with Modbus protocol is also possible.

1)

Provided that the plugs are connected correctly

2)

Depending on the basic material design of the pump

 

 Monitoring

 Intelligent Pressure Sensor

PumpMeter

3

Summary of Contents for PumpMeter

Page 1: ...PumpMeter Type Series Booklet ...

Page 2: ...served Contents provided herein must neither be distributed copied reproduced edited or processed for any other purpose nor otherwise transmitted published or made available to a third party without KSB s express written consent Subject to technical modification without prior notice KSB Aktiengesellschaft Frankenthal 10 11 2010 ...

Page 3: ...ure 30 C to 80 C Operating temperature 10 C to 60 C Technical data of the sensors Characteristics Value Signal 4 20 mA Gauge pressure 40 bar max Enclosure IP 671 Burst pressure 80 bar max Fluid temperature 30 C to 140 C Installation torque 10 Nm Ambient temperature 10 C to 60 C Materials Overview of materials Wetted components Material Pressure sensor measuring unit 1 4542 Pressure sensor process ...

Page 4: ...fficiency Operation near the optimum Third quarter flashing 3 Operation within intended operating range Optimum energy efficiency Operation in overload conditions Fourth quarter flashing 4 Limit of the intended operating range Possibly overload of pump and or motor Design variants Adapter Depending on thread type and size of the pump s pressure gauge connections Cable length 600 mm or 1200 mm depe...

Page 5: ... Accelerator as preparation Propanol 80 Drilling grinding emulsion 60 Cleaning agents Spirits 40 ethanol 60 Juice fruit and sugar juice 60 Service water 60 Nitric acid 15 20 80 Brewery applications Silicate free alkaline degreasing or cleaning solution containing solid particles 0 3 5 80 Beer mash 100 Fuel Beer wort 100 Trisodium phosphate 4 80 Brewing water 60 Water Ice water brewery 60 Deionised...

Page 6: ... 80 Drinking water4 60 Magnesium sulphate 10 80 Permeate osmosis 140 Maleic acid 10 60 Ultrafiltrate permeate pure filtrate solids content 1 30 Milk 60 Deionised water free of solids 60 Lactic acid 5 60 Fully desalinated water 120 Lactic acid 40 60 Hot water brewery 60 Sodium carbonate 6 60 Water treated to VdTÜV1466 140 Sodium hydroxide 5 40 Water with anti freeze pH value 7 5 4 6 110 Sodium nitr...

Page 7: ...ter R 1 4 M8 01186472 Adapter G 1 4 M8 01186474 Adapter R 3 8 M8 01191765 Adapter R 1 2 M8 01191766 Adapter G 3 8 M8 01191857 Adapter G 1 2 M8 01191858 Accessories Overview of accessories Description Ident No Extension cord Length 5 m For extending the sensor cables 01146980 Extension cord Length 10 m For extending the sensor cables 01146981 Connection cable Length 1 m 5 pole cable with M12 plug f...

Page 8: ...KSB Aktiengesellschaft 67225 Frankenthal Johann Klein Str 9 67227 Frankenthal Germany Tel 49 6233 86 0 Fax 49 6233 86 3401 www ksb com 4072 5 2 10 10 11 2010 ...

Reviews: