background image

 

High-efficiency Drinking Water Pump

Calio-Therm NC

 

 

 

 

 

 

Installation/Operating Manual

Summary of Contents for Calio-Therm NC

Page 1: ...High efficiency Drinking Water Pump Calio Therm NC Installation Operating Manual...

Page 2: ...ts provided herein must neither be distributed copied reproduced edited or processed for any other purpose nor otherwise transmitted published or made available to a third party without the manufactur...

Page 3: ...porary Storage Disposal 10 3 1 Checking the condition upon delivery 10 3 2 Transport 10 3 3 Storage preservation 10 3 4 Return to supplier 10 3 5 Disposal 11 4 Description of the Pump Set 12 4 1 Gener...

Page 4: ...on 23 6 5 Returning to service 23 7 Servicing Maintenance 24 7 1 Servicing inspection 24 7 2 Drainage cleaning 24 7 3 Removing the pump set from the piping 24 8 Trouble shooting 26 9 Related Documents...

Page 5: ...pected indicated as sound pressure level LpA in dB A Pump Machine without drive additional components or accessories Pump set Complete pump set consisting of pump drive additional components and acces...

Page 6: ...ly contact your nearest KSB service centre to maintain the right to claim under warranty Noise characteristics see Section 4 6 Page 14 1 2 Target group This operating manual is aimed at the target gro...

Page 7: ...ensure safe pump operation and prevent personal injury and damage to property The safety information in all sections of this manual must be complied with This manual must be read and completely under...

Page 8: ...ersonnel 2 5 Consequences and risks caused by non compliance with this manual Non compliance with this operating manual will lead to forfeiture of warranty cover and of any and all rights to claims fo...

Page 9: ...pump set shall only be performed when it has been disconnected from the power supply de energised The pump casing must have cooled down to ambient temperature Pump pressure must have been released an...

Page 10: ...or damage to the pump Clean and cover pump openings and connections as required prior to putting the pump into storage Store the pump set in a dry protected room where the atmospheric humidity is as c...

Page 11: ...tective mask if required Observe all legal regulations on the disposal of fluids posing a health hazard 1 Dismantle the pump set Collect greases and other lubricants during dismantling 2 Separate and...

Page 12: ...mp NC Fixed speed 25 Nominal diameter of pump nozzle 20 G 1 1 4 25 G 1 1 2 40 Head in m x 10 example 40 4 m 130 Length 130 130 mm 4 3 Name plate 1 2 3 1 2 3 4 5 6 Fig 1 Name plate example 1 Type serie...

Page 13: ...tion 1 230 VAC 50 Hz IP44 enclosure Thermal class F Temperature class TF 110 Interference emissions EN 61000 6 3 Interference immunity EN 61000 6 2 Bearings Product lubricated special plain bearing Co...

Page 14: ...ntegrated cable gland is fastened to the motor housing with 2 screws and can be removed once the screws have been undone in order to connect the power cable to the pump s terminals The fluid enters th...

Page 15: ...4 8 Dimensions and weight For dimensions and weights please refer to the type series booklet of the pump 4 Description of the Pump Set Calio Therm NC 15 of 30...

Page 16: ...The above safety instructions have been complied with 5 3 Installing the pump set Install the pump set in an easily accessible place CAUTION Ingress of fluid into the motor Damage to the pump set Inst...

Page 17: ...ith an assembly tool e g pipe wrench 5 4 Connecting the piping DANGER Excessive loads acting on the pump nozzles Danger to life from leakage of hot fluids Do not use the pump as an anchorage point for...

Page 18: ...trained and qualified electrician Observe regulations IEC 60364 and for explosion proof models EN 60079 DANGER Work performed on an energised terminal box Danger of death from electric shock Switch of...

Page 19: ...Remove the front cover 4 Lead a suitable three phase power cable e g 3 x 0 75 mm2 through the pump s cable gland 5 Strip the cable sheath and cores in accordance with applicable regulations 6 Connect...

Page 20: ...t front cover Risk of fatal injury due to electric shock Risk of injury Only operate the pump with the front cover fitted and with the PE connection earthing established WARNING Hot surface Risk of in...

Page 21: ...ue to insufficient lubrication of shaft seal Damage to the pump set Never operate the pump set without liquid fill Prime the pump as per operating instructions Always operate the pump within the permi...

Page 22: ...TE If the discharge line is equipped with a check valve the shut off element in the discharge line may remain open provided the site s requirements and regulations are taken into account and observed...

Page 23: ...Start up the pump set regularly between once a month and once every three months for approximately five minutes during prolonged shutdown periods This will prevent the formation of deposits within th...

Page 24: ...ty clothing and a protective mask if required Observe all legal regulations on the disposal of fluids posing a health hazard 1 Always flush the pump if it has been used for handling noxious hot or oth...

Page 25: ...s a generator when running in reverse Danger to life from hazardous induction voltage at the motor terminals Prevent the fluid from flowing back by closing the shut off elements The relevant notes and...

Page 26: ...sible cause Remedy1 Pump not connected to power supply Check the fuses and correct connection to power supply If required disconnect the pump from the power supply and re connect it to the power suppl...

Page 27: ...9 Related Documents 9 1 Wiring diagram 1 phase PE L N Fig 4 Wiring diagram for single phase a c current 9 Related Documents Calio Therm NC 27 of 30...

Page 28: ...ic Compatibility Directive 2014 30 EU Low voltage Directive 2014 35 EU The manufacturer also declares that the following harmonised international standards have been applied DIN EN 55014 1 EN 55014 2...

Page 29: ...26 Fluid handled Density 23 I Intended use 7 M Manual functions 13 Misuse 8 N Name plate 12 O Operating limits 22 Operating modes 13 P Piping 17 Preservation 10 23 Product description 12 R Return to...

Page 30: ...1157 881 01 EN KSB Aktiengesellschaft 67225 Frankenthal Johann Klein Str 9 67227 Frankenthal Germany Tel 49 6233 86 0 Fax 49 6233 86 3401 www ksb com...

Reviews: