KSB BOA-H Assembly Instructions Manual Download Page 6

6

Fig. 9

Setting the limit switch(es)

Handwheel with grub screw,

washer and hexagon nut

Limit switch (10) “CLOSED”

Limit switch (10) “OPEN”

Plug (15)

-- Fit the grub screw, the hexagon nut, the washer and the handwheel again.
-- Insert the plug (15).
-- Run the valve to both limit positions, respectively adjusting the limit switch and tightening the screws.
-- The limit switches (10) have snap-action contacts (audible ”click”).
-- After completing the installation and checking the limit switch set (limit switch setpoints adjusted), check the hexagon head bolts

and the remaining studs, and tighten them in accordance with the table entitled ”Bolt tightening torques” (cf. operating manual

0570.8).

-- Check the valve with limit switches for proper functioning.
-- Check the limit switches (10) for correct ”CLOSED” and ”OPEN” function and switching points, as applicable.

This concludes the assembly procedure for the limit switch variant set.
If, for example, the ”OPEN” position does not function properly, adjust the clearance of the switching nut (3) (Fig. 5). Then repeat

all steps described in Fig. 4 to Fig. 8.

Electrical connection

Unscrew the screw to enable

connection

Wire up connections 13, 14 and 21, 22 (behind cover) as follows:
-- NC contact: 21 and 22
-- NO contact: 13 and 14
The scope of supply includes no M16 cable gland (strain relief).

Summary of Contents for BOA-H

Page 1: ...The operating manual 0570 8 must be observed and adhered to in all details For installation of the limit switch set the valve may or may not be in situ However the preferred option is to install the s...

Page 2: ...3 4 Hexagon nut M 5 ISO 4032 8 A2A 12 4 Serrated lockwasher J 5 3 ISO 6798 FSTPHR 11 4 Socket head cap screw M 5 x 35 ISO 4762 8 8 10 1 Limit switch XCK P2110P16 UG1020001 as specified 46001831 9 1 He...

Page 3: ...the valve OPEN Carefully lever off the collar bush interference fit on stem nut CLOSE the valve The valve cannot be operated during the modification work because the handwheel must be removed Dismant...

Page 4: ...could cause malfunctioning Use a hexagon head bolt 6 and spring washer 16 to attach the fixing plate 4 to the threaded bush Fig 6 Fitting the mounting bracket Alternative bracket mounting position Mou...

Page 5: ...be able to rotate on the grub screw 7 Now bolt down the mounting bracket 1 see also Fig 6 Fig 8 Fitting the limit switch es Limit switch 10 OPEN Socket head cap screw 10 with serrated lockwasher 12 an...

Page 6: ...ining studs and tighten them in accordance with the table entitled Bolt tightening torques cf operating manual 0570 8 Check the valve with limit switches for proper functioning Check the limit switche...

Page 7: ...t with ISO M16 x 1 5 cable entry for cable diameter 4 8 mm with metal end plunger B1 Type to EN 50047 Enclosure to DIN EN 60529 IEC 60529 IP 66 IP 67 NC NO normally closed normally open snap action au...

Page 8: ...sellschaft Johann Klein Strasse 9 67227 Frankenthal Germany Tel 49 6233 86 0 fax 49 6233 86 3882 E mail valves ksb com www ksb com Subject to technical modification without prior notice 0570 812 04 EN...

Reviews: