Fig. 1

Exploded view of limit switch set

The set includes

one

limit switch.

A second limit switch is available on request.
Please refer to Fig. 2 (example: DN 50, set 4) regarding

individual components.
Assembly instructions: see Fig. 3 to Fig. 9.

Fig. 2

Parts list for limit switch set (example: DN 50, set 4).

16

1

Spring washer

A 6

DIN 128

A 4

15

1

Protective cap

A 7 x 16 NT

ZN 1252

01183921

14

2

Hexagon head bolt

M 12 x 35

ISO 4017

A2-70

13

4

Hexagon nut

M 5

ISO 4032

8 + A2A

12

4

Serrated lockwasher

J 5.3

ISO 6798

FSTPHR

11

4

Socket head cap screw

M 5 x 35

ISO 4762

8.8

10

1

Limit switch

XCK-P2110P16

UG1020001

as specified

46001831

9

1

Hexagon nut

M 8

ISO 4032

8 + A2A

00182269

8

2

Grub screw

M 6 x 12

ISO 4026

A4-21H

7

1

Grub screw

M 8 x 55

ISO 4026

45H + A2A

01037673

6

1

Hexagon head bolt

M 6 x 12

ISO 4017

8.8 + A2A

5

1

Contact piece

UG1297318

1.4021

4

1

Fixing plate

UG1295815

1.4016

3

1

Switching nut

UG1295756

1.4021

2

1

Threaded bush

UG1295675

1.4021

1

1

Mounting bracket

UG1295367

1.4016

Pos. Qty.

Description

Stock

Halbzeug

Stock

Drawing/Norm-No. Material

Ident-No.

Summary of Contents for BOA-H

Page 1: ...The operating manual 0570 8 must be observed and adhered to in all details For installation of the limit switch set the valve may or may not be in situ However the preferred option is to install the s...

Page 2: ...3 4 Hexagon nut M 5 ISO 4032 8 A2A 12 4 Serrated lockwasher J 5 3 ISO 6798 FSTPHR 11 4 Socket head cap screw M 5 x 35 ISO 4762 8 8 10 1 Limit switch XCK P2110P16 UG1020001 as specified 46001831 9 1 He...

Page 3: ...the valve OPEN Carefully lever off the collar bush interference fit on stem nut CLOSE the valve The valve cannot be operated during the modification work because the handwheel must be removed Dismant...

Page 4: ...could cause malfunctioning Use a hexagon head bolt 6 and spring washer 16 to attach the fixing plate 4 to the threaded bush Fig 6 Fitting the mounting bracket Alternative bracket mounting position Mou...

Page 5: ...be able to rotate on the grub screw 7 Now bolt down the mounting bracket 1 see also Fig 6 Fig 8 Fitting the limit switch es Limit switch 10 OPEN Socket head cap screw 10 with serrated lockwasher 12 an...

Page 6: ...ining studs and tighten them in accordance with the table entitled Bolt tightening torques cf operating manual 0570 8 Check the valve with limit switches for proper functioning Check the limit switche...

Page 7: ...t with ISO M16 x 1 5 cable entry for cable diameter 4 8 mm with metal end plunger B1 Type to EN 50047 Enclosure to DIN EN 60529 IEC 60529 IP 66 IP 67 NC NO normally closed normally open snap action au...

Page 8: ...sellschaft Johann Klein Strasse 9 67227 Frankenthal Germany Tel 49 6233 86 0 fax 49 6233 86 3882 E mail valves ksb com www ksb com Subject to technical modification without prior notice 0570 812 04 EN...