KSB BOA-H Assembly Instructions Manual Download Page 5

Caution

5

Use only the accompanying original bolts; non-compliance will result in loss of warranty cover.

Fig. 7

Fitting the contact piece

Grub screw (7)

Contact piece (5)

Hexagon nut (9)

-- Turn the hexagon nut (9) onto the grub screw (7), and slide the contact piece (5) onto the grub screw (7).
-- Slip the assembly from above into the slot in the mounting bracket (1).
-- Now, turn the grub screw (7) all the way into the fixing plate (4), allowing part of it to protrude.
-- Firmly tighten the hexagon nut (9).
-- Position the mounting bracket (1) such that the contact piece (3) is not blocked. The contact piece (3) must be able to rotate on

the grub screw (7).

-- Now, bolt down the mounting bracket (1); see also Fig. 6).

Fig. 8

Fitting the limit switch(es)

Limit switch (10) ”OPEN”

Socket head cap screw (10) with

serrated lockwasher (12) and

hexagon nut (13)

Limit switch (10)

”CLOSED”

The standard set includes one limit switch (10). A second limit switch is available on option.
Install the limit switch (10; at bottom for ”CLOSED” position or at top for ”OPEN” position):
There are two socket head cap screws (11), each with a serrated lockwasher (12) and a hexagon nut, (13) per limit switch set.
-- The mounting bracket (1) has slotted holes to facilitate setting of the limit switches (10).
-- Mount the limit switches (10) in the desired switching positions, and loosely tighten screws.
Note: The set includes sufficient screws for two limit switches.

Summary of Contents for BOA-H

Page 1: ...The operating manual 0570 8 must be observed and adhered to in all details For installation of the limit switch set the valve may or may not be in situ However the preferred option is to install the s...

Page 2: ...3 4 Hexagon nut M 5 ISO 4032 8 A2A 12 4 Serrated lockwasher J 5 3 ISO 6798 FSTPHR 11 4 Socket head cap screw M 5 x 35 ISO 4762 8 8 10 1 Limit switch XCK P2110P16 UG1020001 as specified 46001831 9 1 He...

Page 3: ...the valve OPEN Carefully lever off the collar bush interference fit on stem nut CLOSE the valve The valve cannot be operated during the modification work because the handwheel must be removed Dismant...

Page 4: ...could cause malfunctioning Use a hexagon head bolt 6 and spring washer 16 to attach the fixing plate 4 to the threaded bush Fig 6 Fitting the mounting bracket Alternative bracket mounting position Mou...

Page 5: ...be able to rotate on the grub screw 7 Now bolt down the mounting bracket 1 see also Fig 6 Fig 8 Fitting the limit switch es Limit switch 10 OPEN Socket head cap screw 10 with serrated lockwasher 12 an...

Page 6: ...ining studs and tighten them in accordance with the table entitled Bolt tightening torques cf operating manual 0570 8 Check the valve with limit switches for proper functioning Check the limit switche...

Page 7: ...t with ISO M16 x 1 5 cable entry for cable diameter 4 8 mm with metal end plunger B1 Type to EN 50047 Enclosure to DIN EN 60529 IEC 60529 IP 66 IP 67 NC NO normally closed normally open snap action au...

Page 8: ...sellschaft Johann Klein Strasse 9 67227 Frankenthal Germany Tel 49 6233 86 0 fax 49 6233 86 3882 E mail valves ksb com www ksb com Subject to technical modification without prior notice 0570 812 04 EN...