KSB BOA-H Assembly Instructions Manual Download Page 1

Caution

0570.812/04-EN

Assembly instructions

Limit switch set

BOA-H DN 15-150 PN 16/25

Material variant EN-GJS-400-18-LT

Fig. 1

Exploded view of limit switch set

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 2

Parts list for limit switch set

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 3

Dismantling

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 4

Fitting the threaded bush

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 5

Fitting the switching nut and fixing plate

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 6

Fitting the mounting bracket

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 7

Fitting the contact piece

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 8

Fitting the limit switch(es)

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 9

Setting the limit switch(es)

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The operating manual 0570.8 must be observed and adhered to in all details.

For installation of the limit switch set, the valve may or may not be in situ. However, the preferred option is to install the set before

the valve itself is mounted in the piping.
Special care must be exercised if the limit switch set is to be fitted with the valve in situ. In this case, safety sections 3.1 to 3.6 of

the operating manual (precautionary notes; pressureless, cool condition of valve, ...) must be complied with under all

circumstances.
See operating manual 0570.8 for bolt tightening torques.
Non-observance could cause leakage around the bonnet flange of the installed valve.

Summary of Contents for BOA-H

Page 1: ...The operating manual 0570 8 must be observed and adhered to in all details For installation of the limit switch set the valve may or may not be in situ However the preferred option is to install the s...

Page 2: ...3 4 Hexagon nut M 5 ISO 4032 8 A2A 12 4 Serrated lockwasher J 5 3 ISO 6798 FSTPHR 11 4 Socket head cap screw M 5 x 35 ISO 4762 8 8 10 1 Limit switch XCK P2110P16 UG1020001 as specified 46001831 9 1 He...

Page 3: ...the valve OPEN Carefully lever off the collar bush interference fit on stem nut CLOSE the valve The valve cannot be operated during the modification work because the handwheel must be removed Dismant...

Page 4: ...could cause malfunctioning Use a hexagon head bolt 6 and spring washer 16 to attach the fixing plate 4 to the threaded bush Fig 6 Fitting the mounting bracket Alternative bracket mounting position Mou...

Page 5: ...be able to rotate on the grub screw 7 Now bolt down the mounting bracket 1 see also Fig 6 Fig 8 Fitting the limit switch es Limit switch 10 OPEN Socket head cap screw 10 with serrated lockwasher 12 an...

Page 6: ...ining studs and tighten them in accordance with the table entitled Bolt tightening torques cf operating manual 0570 8 Check the valve with limit switches for proper functioning Check the limit switche...

Page 7: ...t with ISO M16 x 1 5 cable entry for cable diameter 4 8 mm with metal end plunger B1 Type to EN 50047 Enclosure to DIN EN 60529 IEC 60529 IP 66 IP 67 NC NO normally closed normally open snap action au...

Page 8: ...sellschaft Johann Klein Strasse 9 67227 Frankenthal Germany Tel 49 6233 86 0 fax 49 6233 86 3882 E mail valves ksb com www ksb com Subject to technical modification without prior notice 0570 812 04 EN...

Reviews: