5 Installation at Site
21 of 36
BOA-CVE C/CS/W/IMS/EKB/IMS EKB
DN
BOA-SuperCompact
3)
5.1301
4)
BOA-Compact
5)
5.1301
4)
BOA-W
5.1301
4)
100
8x M16 x 180
8x M16 x 65
8x M16 x 65
125
8x M16 x 200
8x M16 x 65
8x M16 x 65
150
8x M20 x 240
8x M20 x 70
8x M20 x 70
200
12x M20 x 80
12x M20 x 75
12x M20 x 75
Table 8:
Bolt sizes and bolt lengths to DIN EN 1092-2
PN 10/16
DN
BOA-Control/BOA-Control IMS
15
4x M12 x 45
20
4x M12 x 50
25
4x M12 x 50
32
4x M16 x 55
40
4x M16 x 55
50
4x M16 x 55
65
4x M16 x 55
80
8x M16 x 60
100
8x M16 x 65
125
8x M16 x 65
150
8x M20 x 70
200
12x M20 x 75
6)
5.5 Insulation
WARNING
Cold/hot piping and/or valve
Risk of thermal injury!
▷
Insulate the valve.
▷
Fit warning signs.
CAUTION
Condensation forming in air-conditioning systems, cooling systems and
refrigerating systems
Ice forming!
Actuating element blockage!
Damage due to corrosion!
▷
Insulate the valve to prevent diffusion.
For any insulation fitted on the valve observe the following:
▪
The valve's function must not be impaired.
6)
PN 16 only