![KSB BOA-Compact Operating Manual Download Page 18](http://html1.mh-extra.com/html/ksb/boa-compact/boa-compact_operating-manual_2006425018.webp)
5 Installation at Site
18 of 36
BOA-CVE C/CS/W/IMS/EKB/IMS EKB
Note:
max. 4 m/s
min. 10 x DN
min. 5 x DN
Fig. 4:
Installation position of BOA-CVE IMS and BOA-CVE IMS EKB
Model with actuator type EA-B 12
Model with actuator types EA-C 20 to
EA-C 140 and EA-C 3-point
Fig. 5:
Installation position depending on actuator type
Install the actuator with sufficient clearance for removal.
5.3 Preparing the valve
CAUTION
Outdoor installation
Damage due to corrosion!
▷
Provide weather-proof protection to protect the valve against moisture.
1. Thoroughly clean, flush and blow through all vessels, piping and connections.
2. Remove the valve's flange covers before installing it in the piping.
3. Check that the inside of the valve is free from any foreign objects. Remove any
foreign objects.
4. If required, install a strainer in the piping.