background image

AMTROBOX ATEX for zone 22 (Dust)

9

Commissioning

The installation and start--up of the electro--pneumatic actuators must be according to the best safety practices and

mainly:

Piping

:

Starting--up of a new installation requires cleaning the piping by air before connection to the actuator. This will remove any

impurities impossible to eliminate during construction (fillings, flux, paste, PTFE, etc.)

Electric wiring

:

-- The electric components are “CE” marked in accordance with 89/336/EEC and 94/9/EC european directives.

-- The electric supply voltage and the electric values of the signals must be checked before connecting the components.

-- An external earth terminal allows grounding of the metal parts of the control box.

Never uncouple or disassemble the AMTROBOX or its accessories when pressurized or energized.

Make sure to disconnect electrical cables before dismantling.
During the mounting and dismantling of the boxes, take care the correct installation of all sealing gaskets.

Quality and integrity depends of this correct installation.

During workshop or on- site checking, the valve associated with the actuator and its AMTRONIC EEx- ia box can

be operated from full open to full closed position.

This operation may be of a high significant risk of personnal injury if the safety steps required are not taken to

prevent access between the disc and the seat.

CAUTION !

WARNING

Never exceed the values stipulated in this leaflet!

The dust thickness on the box must not exceed 5 mm.

Do not open the box in dust atmosphere.
Do not clean using a compressed air gun to avoid sending dust in the atmosphere.

To remove dust, use a duster a little bit damp.

Electric connections

The electric connection is obtained via 2 packing--gland M20, plastic (for wire dia. 6 to 12) or stainless steel (for wire dia. 7 to 12) or a

Binder connector.

The good tightness of the box depends on cable selection and the tightening level of the packing--gland.

Pneumatic connection

The pneumatic connection is done directly on the actuator or on the solenoid valve fittedon the actuator.

Direct connection

Connection on solenoid valve

Summary of Contents for AMTROBOX Series

Page 1: ...adjustable cams device for position detection makes it very reliable and easy to adjust The electrical connections are made by packing gland or debrochable connector It is equipped with a bicolor vis...

Page 2: ...gh cover version Boxes X1140 and XA1140 Low cover version Boxes X1149 and XA1149 Microswitches fitted on metallic sheet Adjustable cams Printed circuit board with microswitches External earth terminal...

Page 3: ...es on printed circuit board Boxes X1140 and X1149 Description 6 Technical characteristics of proximity detectors wiring diagram adjustment of cams 7 Position detection by microswitches on metallic pla...

Page 4: ...54 1 Q 410 1 629 970 2 81 84 1 932 1 314 970 3 903 1 903 3 412 2 160 99 14 486 1 412 6 81 2 1 900 4 900 5 890 Q 410 2 412 2 747 486 2 486 3 81 18 900 9 Low cover version Boxes X1149 and XA1149 High co...

Page 5: ...ded plug Polyamide 6 6 903 3 Bored plug 932 1 Spring retaining ring Steel 970 1 Identity plate Adhesive polyester 970 2 Instruction notice Untearable paper 970 3 No Air sticker Adhesive polyester Q Pa...

Page 6: ...9 AMTROBOX X 1140 Item Designation Materials 191 1 Support of printed circuit board AMTROBOX X1140 Acetal 191 2 Support of printed circuit board Polyamide 6 6 554 2 Plain washer Stainless steel 62 2 Q...

Page 7: ...AC 14 72 VA AC 15 2 1 5 1 1 0 5 I A Direct current DC I A 24 V 48 V 115 V 230 V DC 12 6 2 0 4 0 2 DC 13 3 1 0 2 0 1 DC 14 0 6 0 15 0 02 0 01 I A Allowable maximum intensity A According to IEC 60947 5...

Page 8: ...n diagram by Binder connector Position detection by microswitches fitted on metallic sheet AMTROBOX XA1140 and XA1149 Various types of microswitches or inductive proximity detectors can be fitted on a...

Page 9: ...on of all sealing gaskets Quality and integrity depends of this correct installation During workshop or on site checking the valve associated with the actuator and its AMTRONIC EEx ia box can be opera...

Page 10: ...or closing Unscrew the two metal screws one turn Adjust triggering of the required detector by turning the coloured screw corresponding to the colour of the cam to adjust Proceed in the same manner w...

Page 11: ...rectives 94 9 EC 89 336 EC EMC and 73 23 EC Low Voltage Description of automation boxes AMTROBOX X1140 AMTROBOX XA1140 AMTROBOX X1149 AMTROBOX XA1149 As per harmonized european standards Electrical eq...

Page 12: ...s Barbanniers 92635 Gennevilliers Cedex France T l 33 1 41 47 75 00 Fax 33 1 41 47 75 10 www ksb com AMTROBOX ATEX for zone 22 Dust 03 11 09 This leaflet is not contractual and may be amended without...

Reviews: