background image

AMTROBOX ATEX for zone 22 (Dust)

5

Common parts

Item

Designation

Materials

160

Cover

Light alloy with cataphoresis coating

210

Shaft

 30% fibreglass

314

Thrust washer

304 type stainless steel

410.1

Q

Cover gasket

Nitrile

410.2

Q

Base plate cover

Nitrile

412.1

Q

O--Ring

Nitrile

412.2

O--Ring

Nitrile

412.6

Rope (High cover version)

Nitrile

486.1

Ball (High cover version)

Stainless steel

486.2

Ball

Steel

486.3

Ball

Steel

554.1

Plain washer

A2--70 stainless steel

626

Sight glass

Transparent polycarbonate

629

Pointer

Polyamide

747

Non return valve sub--assembly

--------------

81--18

Faston snap

--------------

81--2.1

Ground wire

Copper

81--84.1

Wiring diagram

--------------

890

Base

Light alloy with cataphoresis coating

900.1

Cheese--head screw

A2--70 stainless steel

900.4

Sel--cutting screw

Zinc coated steel cl.8--8

900.5

Cheese--head screw

Stainless steel

900.9

Pozidriv screw

Zinc coated steel cl.8--8

903.1

1/4’’ Gas threaded plug

Polyamide 6--6

903.3

Bored plug

--------------

932.1

Spring retaining ring

Steel

970.1

Identity plate

Adhesive polyester

970.2

Instruction notice

Untearable paper

970.3

“No Air” sticker

Adhesive polyester

Q

Parts included in the spare parts kit

Technical data

Environment

Housing material:

molded light alloy AS9U3

Coating:

black cataphoresis

Protection level:

IP 67 with output via packing--gland, IP 65 with output via 12--pin connector

Resistance to impacts:

IK 10

Resistance to vibrations: according to IEC 60068--2--6 Test Fc. Frequency: 5 to 100 Hz. Displacement:

±

1 mm. Acceleration:

±

0,7 g

Electromagnetic compatibility: EN 61000--6--2; EN 61000--6--4

Test standards:

EN 55011; EN 61000--4--2; EN 61000--4--3; EN 61000--4--4; EN 61000--4--5; EN 61000--4--6

Working temperature

from -- 20

°

C up to + 80

°

C

Electric connection

Two packing--gland M 20 plastic (for wire dia. 6 to 12) or metallic (for wire dia. 7 to 12) or one Binder connector (only for ACTAIR and

DYNACTAIR).

Overall dimensions (mm) and weight (kg)

78

209

209

69

50

78

F

View from F

F

View from F

High cover version

Low cover version

Weight: 1.5 kg

Weight: 1.1 kg

144

58

Summary of Contents for AMTROBOX Series

Page 1: ...adjustable cams device for position detection makes it very reliable and easy to adjust The electrical connections are made by packing gland or debrochable connector It is equipped with a bicolor vis...

Page 2: ...gh cover version Boxes X1140 and XA1140 Low cover version Boxes X1149 and XA1149 Microswitches fitted on metallic sheet Adjustable cams Printed circuit board with microswitches External earth terminal...

Page 3: ...es on printed circuit board Boxes X1140 and X1149 Description 6 Technical characteristics of proximity detectors wiring diagram adjustment of cams 7 Position detection by microswitches on metallic pla...

Page 4: ...54 1 Q 410 1 629 970 2 81 84 1 932 1 314 970 3 903 1 903 3 412 2 160 99 14 486 1 412 6 81 2 1 900 4 900 5 890 Q 410 2 412 2 747 486 2 486 3 81 18 900 9 Low cover version Boxes X1149 and XA1149 High co...

Page 5: ...ded plug Polyamide 6 6 903 3 Bored plug 932 1 Spring retaining ring Steel 970 1 Identity plate Adhesive polyester 970 2 Instruction notice Untearable paper 970 3 No Air sticker Adhesive polyester Q Pa...

Page 6: ...9 AMTROBOX X 1140 Item Designation Materials 191 1 Support of printed circuit board AMTROBOX X1140 Acetal 191 2 Support of printed circuit board Polyamide 6 6 554 2 Plain washer Stainless steel 62 2 Q...

Page 7: ...AC 14 72 VA AC 15 2 1 5 1 1 0 5 I A Direct current DC I A 24 V 48 V 115 V 230 V DC 12 6 2 0 4 0 2 DC 13 3 1 0 2 0 1 DC 14 0 6 0 15 0 02 0 01 I A Allowable maximum intensity A According to IEC 60947 5...

Page 8: ...n diagram by Binder connector Position detection by microswitches fitted on metallic sheet AMTROBOX XA1140 and XA1149 Various types of microswitches or inductive proximity detectors can be fitted on a...

Page 9: ...on of all sealing gaskets Quality and integrity depends of this correct installation During workshop or on site checking the valve associated with the actuator and its AMTRONIC EEx ia box can be opera...

Page 10: ...or closing Unscrew the two metal screws one turn Adjust triggering of the required detector by turning the coloured screw corresponding to the colour of the cam to adjust Proceed in the same manner w...

Page 11: ...rectives 94 9 EC 89 336 EC EMC and 73 23 EC Low Voltage Description of automation boxes AMTROBOX X1140 AMTROBOX XA1140 AMTROBOX X1149 AMTROBOX XA1149 As per harmonized european standards Electrical eq...

Page 12: ...s Barbanniers 92635 Gennevilliers Cedex France T l 33 1 41 47 75 00 Fax 33 1 41 47 75 10 www ksb com AMTROBOX ATEX for zone 22 Dust 03 11 09 This leaflet is not contractual and may be amended without...