![KSB AMTROBOX EEx ia General Information Manual Download Page 15](http://html1.mh-extra.com/html/ksb/amtrobox-eex-ia/amtrobox-eex-ia_general-information-manual_2006465015.webp)
AMTROBOX EEx ia
AMTRONIC EEx ia
15
Wiring diagram
The wiring of the angle sensor and transmitter assembly is carried out in workshop, the connection to the current loop is through the
terminal no. 10 for
and on the terminal no. 11 for
.
Two adjustments are available for the zero adjustment (4 mA) and the gain (20 mA).
When the AMTRONIC EEx ia box is delivered with its actuator, the assembly is preadjusted in workshop.
O
range
Gre
en
V
iol
et
Angle sensor
Transmitter
XT42--SI--NIV
Hazardous area
Safe area
+
--
U
0
I
cc
The intrinsically safe parameters concerning the elements could be connected on the terminals 10 and 11,
must not exceed the values below:
CAUTION !
U
0
P
0
C
0
L
0
Icc
30 V
820 mW
60 nF
50 mH
27,5 mA
27 V
980 mW
90 nF
40 mH
30,0 mA
24 V
990 mW
120 nF
51 mH
26,5 mA
21 V
870 mW
190 nF
62 mH
23,5 mA
18 V
750 mW
290 nF
90 mH
20,0 mA
Manufactuer
Barrier reference
Interface
reference
Laboratory
certificate
Gas group
Permitted
areas
GEORGIN
BZC 24/50/1/A1
BZC 24/50/22/A1
LCIE 01 ATEX 6070X
II C
Any
GEORGIN
Converter BXNT1
LCIE 02 ATEX 6104 X
II C
Any
area
AP 3
PROF SI 38--...--PAS
LCIE 03 ATEX 6078 X
II C
Detection of faulty box or angle sensor connections.
0 %
100 %
M
1
2
3
Defect
Transmitter response
wire 1 open
I output
20 mA
wire 2 open
I output
25 mA
wire 3 open
I output
4 mA
No sensor
I output
25 mA
Pneumatic supply -- Pneumatic connection for AMTRONIC
The pneumatic valve works with 50
filtered air.
Before pneumatic connection, check the pipe is without impurities, mainly when starting--up.
As a measure of safety, the box is equipped with a filter in the input port in order to prevent the clogging of the pneumatic
distributor with the impurities.
This filter can be replaced if it is clogged (the distributor don’t work): extract it by means of a screw and put in the port a new
clean filter.
Working pressure from 3.5 to 7 bar (50 to 102 psi).
Pressure connection: port marked ’’P’’.
Exhaust connection: port marked ’’E’’ fitted with a silencer or connectable to
exhaust network.