2 Safety
11 of 72
Amarex N
2.9 Unauthorised modes of operation
Never operate the pump (set) outside the limits stated in the data sheet and in this
manual.
The warranty relating to the operating reliability and safety of the supplied pump
(set) is only valid if the equipment is used in accordance with its intended use.
2.10 Explosion protection
!
DANGER
Always observe the information on explosion protection given in this section when
operating an explosion-proof pump set.
Sections of the manual marked with the symbol opposite apply to explosion-proof
pump sets also when temporarily operated outside potentially explosive
atmospheres.
Only pumps/pump sets marked as explosion-proof
and
identified as such in the data
sheet must be used in potentially explosive atmospheres.
Special conditions apply to the operation of explosion-proof pump sets in accordance
with EC Directive 94/9/EC (ATEX).
Especially adhere to the sections in this manual marked with the symbol opposite.
The explosion-proof status of the pump set is only assured if the pump set is used in
accordance with its intended use.
Never operate the pump (set) outside the limits stated in the data sheet and on the
name plate.
Prevent impermissible modes of operation at all times.
2.10.1 Repair
Special regulations apply to repair work on explosion-proof pumps. Modifications or
alteration of the pump set could affect explosion protection and are only permitted
after consultation with the manufacturer.
Repair work at the flameproof joints must only be performed in accordance with the
manufacturer's instructions. Repair to the values in tables 1 and 2 of EN 60079-1 is
not permitted.