KS THERMA II KSL00355 Installation And Maintenance Manual Download Page 7

11

10

bATTERY REPlAcEMENT

bATTERY REPlAcEMENT

low BatterY IndIcator
the product has an advanced battery level management system consisting of 2 steps. 

In the first step, the battery still has enough power to open and close the solenoid valve 

and allows the solenoid valve to open. 
In the second step the battery might not have enough power to open and close the 

solenoid valve. In this case, the battery level management system does not allow the 

solenoid valve to open. Instead of providing an opening and closing pulse, the systems 

provides two closing pulses. 

BatterY rePlacement InstructIons

6

Place the cap back into place and 

tighten the allen screw.
note: make sure the o-rings are 

still in thier groove.

- do not allow moisture or water into the system while the battery is being replaced.
- the interior of the faucet must be fully dry before reassembling the parts. If it is not fully 

dry, carefully dry it. 

ImPortant: spent batteries should not be disposed of with normal 

household waste. contact your local authority for information on waste 

disposal and recycling. 

1

unscrew the m4x6 allen screw on 

the faucet left hand side and pull 

out the cap.

2

remove the battery cover protec-

tion and disconnect the connec-

tor between the battery and the 

electronic unit.

3

take out the old battery.

4

replace the used battery with a 

new 9V battery (a lithium battery 

is recommended), and connect the 

connector between the battery and 

the electronic unit.

5

Put the battery protection cover 

back on.

old BatterY

coVer

coVer

new BatterY

new BatterY

fIlter cleanIng InstructIons
the system is provided with two stainless steel filters preventing foreign particles to enter 

the lines. It is recommended to clean the filters every six (6) months. If the water flow has 

decreased, this may be because the filters are clogged. the filters can be cleaned as follows: 

1.  shut-off  the water shut off valve. 
2.  disassemble the faucet and remove the filters located between the faucet nuts and the      

     eccentric unions
3.  wash the filters under running water. 
4.  reassemble the parts.
5.  make sure that there is no water leakage. 

care and cleanIng of cHrome and sPecIal fInIsHes
do not use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. 

use of any prohibited cleaning or maintenance products or substances could damage 

the surface of the shower. for surface cleaning of shower use onlY soap and water, then 

wipe dry with clean cloth or towel. when cleaning bathroom tile, the showers should be 

protected from any splattering of harsh cleansers

MAINTENANcE

Summary of Contents for THERMA II KSL00355

Page 1: ...THERMA THERMA II Installation and maintenance guide Electronic wall mounted faucet...

Page 2: ...any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Kassel Sanitar S L assumes no responsib...

Page 3: ...ey 1 x 2 mm Allen key 1 x Faucet body and spout Familiarize yourself with the part names and confirm that the parts are included 1 x Faucet body 1 x Spout 2 x Eccentric unions 2 x Fixation accessories...

Page 4: ...nt All plumbing is to be installed in accordance with applicable codes and regulations Faucet installation STEP 1 INSTALLINGTHE Faucet 1 Shut off the water supply NOTE The standard distance between th...

Page 5: ...SEC TIONTITLED SETTING ADJUSTMENT The faucet has been factory calibrated to 38 C under ideal installation conditions Due to variations in site conditions the mixed water temperature may need adjustme...

Page 6: ...he button once Securitytime The Security time prevents continuous flushing of water due to reflections or vandalism By default if the sensor is covered for more than 90 seconds the water flow will shu...

Page 7: ...er protec tion and disconnect the connec tor between the battery and the electronic unit 3 Take out the old battery 4 Replace the used battery with a new 9V battery a Lithium battery is recommended an...

Page 8: ...e of reflection 2 Sensor is picking up reflections from the washbasin or another object Remove clean re install Filter or aerator is clogged Water flow diminished TROUBLESHOOTING KASSEL SANIT R S L wa...

Page 9: ...Kassel Sanit r S L Avda de Castilla 1 Pol gono Industrial 28830 San Fernando de Henares Madrid Spain Daimlerstra e 2 D 93133 Burglengenfeld Germany Tel 34 916 778 993 Fax 34 916 777 774 info kassel e...