FILLING THE  SOAP TANK

1

Unscrew the soap tank from the pump assembly 

and pull it out from the bottle support.

2

Fill the bottle with liquid soap to the top line. 

Make sure the bottle is clean before filling it with 

soap.

3

Insert the bottle back into the bottle support.

4

Screw the soap tank back into the pump 

assembly. Make sure the tank is firmly secured 

into place.

5

Press and hold  the refill button located at the back 

of the pump assembly until soap is dispensed 

from the soap dispenser spout. 
Release the button once soap begins dispensing 

from the spout. 
Alternately, use the FILL function on the remote 

control (if available). see page 13/14.
Note: When the soap in the soap tank reaches the 

bottom line, the tank needs to be refilled. 

To refill the soap tank please refer to steps 1-5.

INSTALLATION

8

Insert the MF soap dispensers’ pipes to 

the holes in the soap tank cap. Ensure the 

soap pipe reaches the bottom of the soap 

tank and is not bent or curved.

!

NOTE: The Top filling Multifeed Kit 

enables installing up to 6 soap dispensers 

simultaneously. When installing less than 

6 soap dispensers, make sure to plug the 

remaining holes with the provided plugs.

STEP 3 – CONNECTING THE POWER SOURCE

1

Connect the matching 4 contact connector 

extending from the soap dispenser body 

to the pump connector. 

For FOAM version,

 connect the matching 

connector from the foam dispenser 

body to the compressor unit, and the 

compressor unit to the pump connector.
Please note that since the connector is 

water proof, some pressure must be 

applied for a prefect seal.

O-RING VISIBLE – 

NOT CONNECTED PROPERLY 

ONLY THE GROOVES ARE VISIBLE – 

CONNECTED PROPERLY

IMPORTANT: 

The 4 contacts connector should be connected properly so that the white 

o-ring is not visible and a clicking sound is heard.

PAY ATTENTION:

 If the 4 contacts connectors are not connected properly, the pump will 

not operate properly.

2

Connect the transformer connector to the 

matching connector from the sensor and 

plug the transformer into the electricity 

socket.

 FROM THE TRANSFORMER TO THE SOAP DISPENSER

3

Wait about 10 seconds before placing your 

hands within the sensor range to avoid 

adjustment mode.

10

SECONDS

ABOUT

Summary of Contents for BAIONA N KSL00927

Page 1: ...A N SOAP DISPENSER BAIONA N ESPUMA FOAM DISPENSER TOUCH FREE DECK MOUNTED SOAP DISPENSERS I N STA L L AT I O N A N D M A I N T E N A N C E G U I D E I N STA L L AT I O N A N D M A I N T E N A N C E G...

Page 2: ...it r S L assumes no responsibility for errors or omissions in the information presented in this document In no event shall Kassel Sanit r S L be liable for any special incidental indirect or consequen...

Page 3: ...ep a minimum distance of 1 50 meters between the soap dispenser and any other objects IMPORTANT Keep in mind that when using the faucet installed next to the soap dispenser the user hands should not i...

Page 4: ...re that all the parts are included in your package 12VTRANSFORMER FOAM SOAP DISPENSER PS SOAP DISPENSER 1 X FOAM DISPENSER BODY 1 X FOAM COMPRESSOR WITH PIPE 12VTRANSFORMER 1 X PUMP ASSEMBLY WITH BOTT...

Page 5: ...nser to the right length as required by the installation In order for the pipe to reach the bottom of the tank make sure that the end of the pipe is approximately 2 cm longer than the tank inner base...

Page 6: ...ifeed Kit enables installing up to 6 soap dispensers simultaneously When installing less than 6 soap dispensers make sure to plug the remaining holes with the provided plugs STEP 3 CONNECTING THE POWE...

Page 7: ...E Keep in mind the maximum distance between the Multifeed dispenser pump and the Multifeed Kit should not exceed 3 meters 4 Place the soap tank under the deck or into the tank support TOP FILLING PROF...

Page 8: ...Ensure the tube fully covers the cap outlet and the two o rings on the outlet 7 Connect the breathe pipe to the breathe nozzle in the cap Ensure both the breathe pipe and the corrugated tube are conne...

Page 9: ...nsing from the spout priming is complete press the FILL button again to stop the priming before the minute is over Indication continuous solid LED light in the sensor eye If available the soap dispens...

Page 10: ...he surface of the soap dispenser For surface cleaning use ONLY soap and water then wipe dry with a clean cloth or towel When cleaning bathroom tiles the soap dispenser should be protected from any spl...

Page 11: ...bad or lapsed maintenance Foreign bodies dirt or scale introduced by the water supply or soap tank Use of the soap outside of viscosity specifications Alteration of the original soap foam dispenser co...

Page 12: ...For part numbers see spare parts list Refill button on pump does not activate the pump Sensor is not blinking when hand is placed in front Battery Check operation with functioning battery pack Where...

Page 13: ...Kassel Sanit r S L Avda de Castilla 1 Pol gono Industrial 28830 San Fernando de Henares Madrid Spain Daimlerstra e 2 D 93133 Burglengenfeld Germany Tel 34 916 778 993 Fax 34 916 777 774 info kassel e...

Reviews: