14
CONTROL PANEL
•
1 General switch
•
2 Display
•
3 Detergent switch
•
4 Steam adjustment knob
•
5 Connector block for hose
•
7 Water tank cap
•
8 Detergent tank cap
•
9 Vacuum switch
•
9a Dirtwater bucket
PREPARATION and START TO USE
Open the cap (7) and fill the tank with tap water.
-Note:
If
the
water
available
should
be
"very hard"(>20°F), It is recommended the use of 50%
demineralized water or distilled water,
(this to avoid
excessive limestone formations and to be sufficiently
conductive)
ATTENTION: Do not add detergents, anti-limestone
solutions or essential oils in the water tank boiler (7),
these can cause irreparable damage to the boiler and
circuits.
-Fill the detergent tank (8) with a no-foam detergent.
-Hook the dirtwater bucket (9a)
-Connect the plug to a socket on an electrical
interconnection conformed to the rules of the country,
equipped with a switch and an earth terminal efficient.
START TO USE:
Turn the main switch on (1). The pump will charge the
boiler before starting to heat.
The display (2) will turn on and indicate for a couple of
seconds the revision index of the PCB, the liter of water
consumed and will proceed with the temperature-
pressure status (HEAT) of the machine. When the
machine is ready, it will display "GO". (normally the
machine takes about 4 minutes to reach the ready state.)
Choose the most suitable accessory for the needed use
and connected it to the multifunction handle (14), by
means of the extension tubes, then insert the hose
connector to the block (5), push until you hear a click.
•
10 Steam delivery switch
•
11 Vacuum switch
•
12 Detergent switch
•
13 Lock for steam delivery switch (10)
•
14 Tubes/accessories attachment
When the machine is ready, to release steam through
the handle of the flexible, press the button (10). Now
use the brush or accessory in the surfaces to be
cleaned.
Attention
: it is recommended to perform the first
release of steam after the heating on a container for
about a minute, this is to collect any condensate water
generated in the initially cold ducts.
Attention
: if you are working on delicate
surfaces or things, keep the steam jet at an
adequate distance of at least 20-40cm.
DETERGENT USE (3):
If you need to use detergent check and fill the tank (8),
turn the function on by pushing the button (3) on the
front panel (CHEM), keep it pushed to regulate the
ejection level (2 to 16) by seeing it changing on the
display. Now push button (12) on the handle in order to
start releasing detergent on the surface to be cleaned.
To stop it, push again button (3) (C.Off).
VACUUM USE:
Before vacuuming, take the bucket (9a) off and check
that the filter is in place. Control if the switch (9) is
turned on. Now press button (11) and you can vacuum
dirt and liquid (in the display you will see “MAH”
showing the activation of max. vacuum). When the
bucket (9a) is full with dirty water, the vacuum noise
changes and then stops; stop the machine immediately
and empty the bucket. When vacuuming operations
are done, it is advised to clean the filter and dry the
bucket or let it open so that it can dry itself.
STEAM RELEASE REGULATION
:
Through the regulation knob (4) placed frontally on the
machine, you can gradually adjust the release of the
steam.
END OF WATER
: The acoustic and the visual indicator
of the display (2), indicates when there is no more
12
11
10
14
13
Summary of Contents for KGVC3000