Parameter
Description
ReadAfterDete
ct Password0
….
ReadAfterDete
ct Password3
The password to be used to access to tag’s memory in ReadAfterDetect mode. Use a
‘0’ password if the access password is not requested.
ReadAfterDete
ct Bank
The tag’s memory bank to access in ReadAfterDetect mode:
•
0x00: Reserved;
•
0x01: EPC;
•
0x02: TID;
•
0x03: User.
ReadAfterDete
ct Address0
…
ReadAfterDete
ct Address3
The tag’s memory start address to access in the specified memory bank in
ReadAfterDetect mode.
ReadAfterDete
ct Length
The number of tag’s memory blocks (2-bytes length) to access in the specified
memory bank in ReadAfterDetect mode. In case of Reserved or User bank selected, 0
means no tag’s memory block access; in case of TID bank selected, 0 means auto-
length (class identifier, manufacturer identifier, serial number).
ReadAfterDete
ct Info Flags
The tag’s info (PC, EPC, CRC) to include in the tag’s ID in ReadAfterDetect mode. A
byte whose bits are dedicated to disable (0 value) or enable (1 value) functions:
•
Bit 7: Not used;
•
Bit 6: Not used;
•
Bit 5: Not used;
•
Bit 4: Not used;
•
Bit 3: Not used;
•
Bit 2: CRC field;
•
Bit 1: EPC field;
•
Bit 0: PC field.
Q
Minimum and maximum Q value to be used in dynamic Q selection algorithm:
•
High nibble: minimum Q value (0x0 … 0xF);
•
Low nibble: maximum Q value (0x0 … 0xF).
Q Adjust
Rounds
Maximum Q adjust rounds in dynamic Q selection algorithm.
Inventory
Cycles
The inventory cycles in inventory command.
3.2.3
Dynamic Power Management
This section provides details on the configurable dynamic power management
parameters of the
BLUEBOX