4 Mounting
OPTISOUND 3030 C • Foundation Fieldbus
51118-EN-210701
Fig. 9: Orientation in solids
To reduce the min. distance to the medium, you can also mount OP-
TISOUND 3030 C with a beam deflector. By doing this, it is possible
to fill the vessel nearly to maximum. Such an arrangement is suitable
primarily for open vessels such as e.g. overflow basins.
45°
~200 mm
(7.87")
~400 mm x 400 mm
(15.75" x 15.75"
)
Fig. 10: Beam deflector
The ultrasonic sensor should be installed at a location where no
installations cross the ultrasonic beam.
Vessel installations such as for example, ladders, limit switches, heat-
ing spirals, struts etc. can cause false echoes that interfere with the
useful echo. Make sure when planning your measuring site that the
ultrasonic signals have a "clear view" to the measured product.
In case of existing vessel installations, a false signal suppression
should be carried out during setup.
If large vessel installations such as struts or supports cause false
echoes, these can be attenuated through supplementary measures.
Small, inclined sheet metal or plastic baffles above the installations
scatter the ultrasonic signals and avoid direct false echoes.
Vessel installations