Medium Control Unit
64
Pos : 19.26.8 /BA/Info-Center/Ladewagen/M edi um/Kratzbodenvorlauf akti vieren bei m Entladevorgang (L/GL_Ausführ ung) @ 28\mod_1249976245130_78.doc @ 272790
8.11.3
Activating the floor conveyor supply during unloading (L/GL design only)
•
Pressing the key (11) once
activates the floor conveyor supply. (Pilot
lamp (11) lit).
•
By pressing the key (11) again,
the floor conveyor supply will be
deactivated (pilot lamp (11) goes out).
Pos : 19.26.9 /BA/Info-Center/Ladewagen/M edi um/Kratzbodenvorlauf Eilgang eins chalten (L/GL_Ausführung) @ 28\mod_1249977501598_78.doc @ 272815
8.11.4 Switching on rapid traverse during unloading (L/GL design only)
•
Pressing the key (12)
activates rapid traverse (pilot lamps (11+12) are
lit).
•
By pressing the key (12) again,
the floor conveyor supply (rapid
traverse) will be deactivated (pilot lamps (11+12) go out).
Pos : 19.26.10 /BA/Info-C enter/Ladewagen/Medi um/Kr atz boden- Anfangsgeschwi ndig keit (D/GD_Ausführ ung) @ 28\mod_1249975321364_78.doc @ 272740
8.11.5
Setting of the initial speed of the floor conveyor for the unloading process (D/GD design
only)
The setting for the initial speed of the floor conveyor is made with the tailgate closed.
Use the key
or
to increase or decrease the speed of the floor conveyor.
Read off the set value on the bar graph (21).
Pos : 19.26.11 /BA/Info-C enter/Ladewagen/Medi um/Kr atz bodenvorlauf akti vier en bei m Entladevorgang (D/GD _Aus führung) @ 28\mod_1249977941067_78.doc @ 272840
8.11.6 Activating the floor conveyor supply during unloading (D/GD design only)
•
Pressing the key (12) once
activates the floor conveyor supply. (Pilot
lamp (12) lit).
•
Use the key
or
to increase or decrease the speed of the floor conveyor (Read
off the set value on the bar graph (21). The value is not stored).
•
By pressing the key (12) again,
the floor conveyor supply will be
deactivated (pilot lamp (12) goes out).
Pos : 19.26.12 /BA/Info-C enter/Ladewagen/Medi um/Kr atz bodenvorlauf Eilgang ei nsc halten (D/GD _Ausführ ung) @ 28\mod_1249978784505_78.doc @ 272865
8.11.7
Switching on rapid traverse during unloading process (D/GD design only)
•
Pressing the key (13)
activates rapid traverse (indicator lamp (12)
flashes).
•
By pressing the key (13)
again, the floor conveyor supply (rapid
traverse) will be deactivated (indicator lamp (12) goes out).
Pos : 19.26.13 /BA/-----Seitenumbr uch------ @ 0\mod_1196175311226_0.doc @ 4165
Summary of Contents for MX 310 GD
Page 20: ...Safety 20 MX000003 7 8 9 7 7 1 2 5 6 6 8 11 4 4 11 9 4 5 3 3 9 4 5 9 GL GD 10 GD GL Fig 3 ...
Page 52: ...Driving and Transport 52 Pos 18 BA Sei tenumbruch 0 mod_1196175311226_0 doc 4165 ...
Page 213: ...Maintenance 213 ...
Page 218: ...Maintenance lubrication chart 218 14 5 Lubrication chart GD MX000006 Fig 148 ...
Page 243: ......