![Krone BiG Pack 870 HDP XC Original Operating Instructions Download Page 226](http://html1.mh-extra.com/html/krone/big-pack-870-hdp-xc/big-pack-870-hdp-xc_original-operating-instructions_2004796226.webp)
15
Settings
15.20 Checking/setting Variable Filling System (VFS)
226
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
Tension the spring (2), see chapter settings “Setting spring zero adjuster”.
Set the rubber buffer at the zero adjuster,
Checking the clearance of the ratchet
.
Turn the flywheel manually in working direction (
) until the roll (4) engages
again in the zero adjuster (3).
Make sure that tripping ratchet (6) does not move during the whole process.
15.20.4
Setting the rubber pad on the zero adjuster
BP000-236
ü
The machine is shut down and safeguarded,
.
ü
The Variable Filling System (VFS) is in zero position,
.
Place or remove washers under the rubber buffers (16) until the dimension is
X=0–2 mm
.
15.20.5
Checking/setting spring at zero adjuster
BP000-237
In the factory, the spring (2) is set to dimension
X=185 mm
.
ü
The machine is shut down and safeguarded,
.
ü
The Variable Filling System (VFS) is in zero position,
.
Check dimension X.
ð
If the dimension is
X=185 mm
, the setting is correct.
ð
If the dimension is
not X=185 mm
, the spring (2) must be set.
Set the spring (2) to dimension
X=185 mm
.