GB-4
D
GB
F
NL
I
E
Hot-air generation:
▷
At flow velocities of > 15 m/s, the protective
flame tube FPT is used to protect the flame from
being cooled.
Installation on the furnace
▷
When installing, always ensure that when the
burner is mounted, it is sealed tightly on the
furnace wall.
2
3
1
4
Air connection, gas connection
GA
LA
Type
Gas connection
GA
Air connection
LA
ZIO 165
Rp 1½
DN 100
ZIO 200
Rp 2
DN 150
▷
Threaded connection to DIN 2999, flange dimen-
sions to DIN 2633, PN 16.
▷
Install flexible tubes or bellows units to prevent
mechanical stress or transmission of vibration.
▷
Ensure that the seals are undamaged.
DANGER
Risk of explosion! Ensure the connection is gas-
tight.
For connecting to ANSI/NPT connections:
▷
An adapter set is required for connection to ANSI/
NPT, see page 12 (Accessories).
Type
Gas connection
GA
Air connection
LA*
ZIO 165
1½ – 11.5 NPT
4.57"
ZIO 200
2 – 11.5 NPT
6.72"
* Flange hole diameter.
▷
Weld flange
H
to air pipe
P
. Use NPT thread
adapter
G
for gas connection
GA
.
GA
G
H
P
LA
Ignition lance connections on the ZIO..L:
▷
Air connection
la
.
▷
Gas connection
ga
.
▷
Ignition lance capacity: 1.5 kW.
la
ga
Type
Ignition lance
gas connection
ga
Ignition lance
air connection
la
ZIO..L
Rp ¼
Rp ½
ZIO..L with
adapter set
¼" NPT
½" NPT