Before calling service: 

 

Problem

 

Caus

 

How to fix it 

 

The machine is too noisy 

 
 

 

 

The machine does not work: 

 
 
 

 
 

 

The machine is turned 
on, but does not cool: 

 
 
 

 

Fittings do not seal properly 

 

There is a fallen 

object in the machine. 

 

There is a fallen object 

in the area of the fan. 

 

The power cable is 
not connected. 

 

Socket does not work. 

 

The main switch is not 

turned on or the 

thermostat is set to ,,0 ”. 

 

Ventilation holes 
are covered. 

 

The machine has a 
dirty condenser. 

 

The tube is not 
inserted correctly. 

 

damage to the tube 

 

Remove the object that is not in contact with 
the cooling machine. 

 

Remove the object from the fan area. 

 

 

Connect the power cord into the socket. 

 
 

 

Turn on the power switch and set the 
thermostat to the desired value. 

 

Remove anything from the vent holes. 

 

Remove the coarse dirt and wipe off the dust. 

 

 

Pull out the tube, check for any sharp edges, 
and if there are, cut with knife. 

 

Pull out the tube and shorten 2cm. 

 

If, after the above recommended checks the fault 
still persists, please contact customer service. 

 

Do not forget to specify the following: 

 

 

type of defect

 

type of product

 

product serial number (listed on the label)

 

Ordering parts: 

 

ALWAYS USE ORIGINAL PARTS. 

 

The  manufacturer  or  supplier  does  not  take  any 
res-ponsibility for parts which are not original or re-
commended by the manufacturer. 

 

Technical specifications: 

 

The  technical  label  is  located  on  the  external  front  side 
(under the control panel) of the machine  or  on  the inside 
divider. The CWP -100, CWP-200, CWP 300, CWP - 200 

mobile  and  CWP-300  mobile  have  the  label  on  the 
outside shell on the front of the machine. 

 
 

Summary of Contents for AS-110

Page 1: ......

Page 2: ...st be installed by appropriately trained staff More detailed maintenance such as cleaning and servicing the cooling system must be performed by authorized technicians who are familiar with cooling and electrical systems CAUTION If the supply cord is damaged it must be replaced by the manufacturer its service technicians or similarly qualified person in order to avoid dangerous situations Installat...

Page 3: ...oil 11 plastic tank 12 motor compressor 13 overflow 2 8 5 9 6 4 10 1 13 12 11 3 7 Model series of CWP 11 3 10 1 4 6 Connection 1 Fill the plastic tank No 11 with water right up to the overflow No 13 CAUTION After connecting the cooling coil the water level may drop in the plastic tank so check again and add water if necessary 2 Connect the cooling ma Python 4 2 chine with dispense tower output and...

Page 4: ...ut even more into the tube THE TUBE MUST NOT BE UNDER PRESSURE WHEN DISCONNECTING Regular and the scheduled maintenance services Regarding routine maintenance the information contained in this manual is intended for a regular operating staff which must be properly trained Regarding any emergency or scheduled maintenance the contained information is intended for professional staff only The basic sa...

Page 5: ... soak in a chemical solution and clean thoroughly to remove any residue left by the beer Special maintenance This chapter provides information for a qualified persons only check the correct functioning of the circuit broker and a status of power cord check whether there is a noticable change in a machine operation If you need to order replacement parts it is always necessary to state the type and ...

Page 6: ...8mm 7 Beverage 6 CO2 N2 4 4 CO2 N2 3 5 3 5 or compressor 8 8 10 9 11 Beverage 1 2 Connection with dispense tower B AS 80 coil 2x 1 Beverage inlet 2 Beverage outlet the beverage runs through the python tubing 2 2 No 12 illustration 3 Tray for the clarifier 4 Dispense head S type A type M type 5 Plastic fitting F 5 8 x9 5mm 6 Plastic fitting F 5 8 x 8 mm 7 Plastic fitting splitter 8 x 8 x 8mm 8 Pres...

Page 7: ...ense head S type A type M type 5 Plastic fitting F 5 8 x9 5mm 6 Plastic fitting F 5 8 x 8 mm 7 Plastic fitting splitter 8 x 8 x 8mm 3x 8 Pressure reducer 1 way N2 CO2 N2 CO2 9 Beverage 10 Plastic fitting JG SS 9 5 x8mm 4x 11 Plastic fitting JG straight 12 7 x8mm 2x 8 Beverage Beverage 7 5 5 6 4 6 4 7 9 9 CO2 N2 or compressor Beverage 3 5 CO2 N2 6 4 9 5 6 4 9 ENGLISH 11 10 12 2 1 Beverage 6 ...

Page 8: ... thermostat to the desired value Remove anything from the vent holes Remove the coarse dirt and wipe off the dust Pull out the tube check for any sharp edges and if there are cut with knife Pull out the tube and shorten 2cm If after the above recommended checks the fault still persists please contact customer service Do not forget to specify the following type of defect type of product product ser...

Page 9: ...0Hz 50Hz Amperage 1 27A 1 70A 2 90A 4 00A 4 50A 3 40A 4 00A 4 00A 4 50A 4 50A Power input 292W 391W 667W 920W 1035W 782W 920W 920W 1035W 1035W or wattage Ice bank 4 8kg 5 10kg 10 20kg 10 30kg 10 30kg 0 2kg 0 5kg 0 5kg 0 5kg 0 5kg Refrigerant R 134a R 134a R 134a R 290 R 290 R 134a R 290 R 290 R 290 R 290 Capacity of water 14l 20l 38l 58l 58l 14l 20l 20l 38l 38l tank Draught of re 1 2m 7m 7m 8m 8m ...

Reviews: