fan cover
direction of pulling
10. Cover (No. 7)
Take off the fan.
condenser
11. Unscrew the fastening
screws from the cooler on
the side where the con-
denser is placed.
(picture 3.1 and 3.2.)
12. First, pull out the
loosen cover about 3 cm
in a upward direction
(picture 4.1.), then pull to
the
side
(pic.
4.2).
Loosen the other side of
the cover so you can pull
out the whole cover from
the metal slides.
4.2.
direction of pulling
13. Now you can clean the
condenser by brushing or
by the air pressure
from both sides.
fan cover
3.1.
3.2.
4.1.
direction
of pulling
ENGLISH
Periodic checks
check, if the power supply plug is firmly
plugged into the socket.
check that the machine is not exposed to
radiant heat
check the level and cleanliness of the water bath
in the plastic container (No.11) (after six months of
operation we recommend to replace the
water bath)
the condenser of the cooling unit should
be cleaned regularly
sanitizing
When sanitizing
do not forget
to also sanitize
the dispensing tap and the dispense head. You
need to disassemble them, then soak in a
chemical solution and clean thoroughly to
remove any residue left by the beer.
Special maintenance:
This chapter provides information for a
qualified persons only.
check the correct functioning of the circuit
broker and a status of power cord.
check whether there is a noticable change in a
machine operation.
If you need to order replacement parts, it is always
necessary to state the type and serial number of
the machine. This is written on the label.
Electrical connection:
The machine should be connected to the power
supply 220-240V 50Hz, 16A fuse. Plug circuit wiring
must comply with applicable regulations of IEC, EN
and ISO standards. If the power cord (cable) is
damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified person in order
to avoid dangerous situations.
Potential areas of risk, risks which cannot be
removed.
Risks related to the electricity:
Potential risks are removed thanks to the
construction of the electrical system according to
CSN 331500, EN, and ISO norms.
Note:
Electrical machine must be checked within scheduled
dates according to CSN norm by the authorized person.
Service, spare parts, required inspections and check ups
are carried out and provided by the Lindr company.
4