background image

 

 

fan cover 

 

 

 

direction of pulling 

 

 
 
 

 

10. Cover (No. 7) 
Take off the fan. 

 

condenser 

 

 
 
 

 

 

11.  Unscrew  the  fastening 
screws  from  the  cooler  on 
the  side  where  the  con-
denser is placed. 

 

(picture 3.1 and 3.2.) 

 
 

 
 

 

12.  First,  pull  out  the 
loosen  cover  about  3 cm 
in  a  upward  direction 
(picture 4.1.), then pull to 
the 

side 

(pic. 

4.2). 

Loosen  the  other  side  of 
the cover so you can pull 
out the  whole cover from 
the metal slides. 

4.2. 

direction of pulling 

 

 

13. Now  you can clean the 
condenser  by  brushing  or 
by the air pressure 

 

from both sides. 

 
 
 

 
 
 

 
 
 

 
 

 

fan cover 

 
 
 

 
 
 

 
 

 

3.1. 

 

 

3.2. 

 

 
 
 

 
 
 

 
 
 

 

4.1. 

direction 

of pulling

 

ENGLISH 

Periodic checks 

 

 

check,  if  the  power  supply  plug  is  firmly 

plugged into the socket.

 

check  that  the  machine  is  not  exposed  to 

radiant heat

 

check the level and cleanliness of the water bath 
in the plastic container (No.11) (after six months of

 

operation we recommend to replace the 
water bath) 

 

 

the condenser of the cooling unit should 

be cleaned regularly 

 

 

sanitizing

When sanitizing 

do not forget

 to also sanitize 

the dispensing tap and the dispense head. You 
need to disassemble them, then soak in a 
chemical solution and clean thoroughly to 
remove any residue left by the beer. 

 

Special maintenance: 

 

This chapter provides information for a 
qualified persons only. 

 

 

check  the  correct  functioning  of  the  circuit 

broker and a status of power cord.

 

check whether there is a noticable change in a

 

machine operation. 

 

If you need to order replacement parts, it is always 
necessary to state the type and serial number of 
the machine. This is written on the label. 

 

 

Electrical connection: 

 

The  machine  should  be  connected  to  the  power 
supply  220-240V  50Hz,  16A  fuse.  Plug  circuit  wiring 
must  comply  with  applicable  regulations  of  IEC,  EN 
and  ISO  standards.  If  the  power  cord  (cable)  is 
damaged,  it  must  be  replaced  by  the  manufacturer, 
its service agent or similarly qualified person in order 
to avoid dangerous situations. 

 

Potential areas of risk, risks which cannot be 

 

removed. 

 

Risks related to the electricity: 

 

Potential  risks  are  removed  thanks  to  the 
construction  of  the  electrical  system  according  to 
CSN 331500, EN, and ISO norms. 

 

Note: 

 

Electrical  machine  must  be  checked  within  scheduled 

dates  according  to  CSN  norm  by  the  authorized  person. 

Service, spare parts, required inspections and check ups 

are carried out and provided by the Lindr company. 

 

Summary of Contents for AS-110

Page 1: ......

Page 2: ...st be installed by appropriately trained staff More detailed maintenance such as cleaning and servicing the cooling system must be performed by authorized technicians who are familiar with cooling and electrical systems CAUTION If the supply cord is damaged it must be replaced by the manufacturer its service technicians or similarly qualified person in order to avoid dangerous situations Installat...

Page 3: ...oil 11 plastic tank 12 motor compressor 13 overflow 2 8 5 9 6 4 10 1 13 12 11 3 7 Model series of CWP 11 3 10 1 4 6 Connection 1 Fill the plastic tank No 11 with water right up to the overflow No 13 CAUTION After connecting the cooling coil the water level may drop in the plastic tank so check again and add water if necessary 2 Connect the cooling ma Python 4 2 chine with dispense tower output and...

Page 4: ...ut even more into the tube THE TUBE MUST NOT BE UNDER PRESSURE WHEN DISCONNECTING Regular and the scheduled maintenance services Regarding routine maintenance the information contained in this manual is intended for a regular operating staff which must be properly trained Regarding any emergency or scheduled maintenance the contained information is intended for professional staff only The basic sa...

Page 5: ... soak in a chemical solution and clean thoroughly to remove any residue left by the beer Special maintenance This chapter provides information for a qualified persons only check the correct functioning of the circuit broker and a status of power cord check whether there is a noticable change in a machine operation If you need to order replacement parts it is always necessary to state the type and ...

Page 6: ...8mm 7 Beverage 6 CO2 N2 4 4 CO2 N2 3 5 3 5 or compressor 8 8 10 9 11 Beverage 1 2 Connection with dispense tower B AS 80 coil 2x 1 Beverage inlet 2 Beverage outlet the beverage runs through the python tubing 2 2 No 12 illustration 3 Tray for the clarifier 4 Dispense head S type A type M type 5 Plastic fitting F 5 8 x9 5mm 6 Plastic fitting F 5 8 x 8 mm 7 Plastic fitting splitter 8 x 8 x 8mm 8 Pres...

Page 7: ...ense head S type A type M type 5 Plastic fitting F 5 8 x9 5mm 6 Plastic fitting F 5 8 x 8 mm 7 Plastic fitting splitter 8 x 8 x 8mm 3x 8 Pressure reducer 1 way N2 CO2 N2 CO2 9 Beverage 10 Plastic fitting JG SS 9 5 x8mm 4x 11 Plastic fitting JG straight 12 7 x8mm 2x 8 Beverage Beverage 7 5 5 6 4 6 4 7 9 9 CO2 N2 or compressor Beverage 3 5 CO2 N2 6 4 9 5 6 4 9 ENGLISH 11 10 12 2 1 Beverage 6 ...

Page 8: ... thermostat to the desired value Remove anything from the vent holes Remove the coarse dirt and wipe off the dust Pull out the tube check for any sharp edges and if there are cut with knife Pull out the tube and shorten 2cm If after the above recommended checks the fault still persists please contact customer service Do not forget to specify the following type of defect type of product product ser...

Page 9: ...0Hz 50Hz Amperage 1 27A 1 70A 2 90A 4 00A 4 50A 3 40A 4 00A 4 00A 4 50A 4 50A Power input 292W 391W 667W 920W 1035W 782W 920W 920W 1035W 1035W or wattage Ice bank 4 8kg 5 10kg 10 20kg 10 30kg 10 30kg 0 2kg 0 5kg 0 5kg 0 5kg 0 5kg Refrigerant R 134a R 134a R 134a R 290 R 290 R 134a R 290 R 290 R 290 R 290 Capacity of water 14l 20l 38l 58l 58l 14l 20l 20l 38l 38l tank Draught of re 1 2m 7m 7m 8m 8m ...

Reviews: