T
ransistor output
N
umber
,
function
1
output
,
synchronously switching with the
relay
G
alvanic separation
fl
oating
M
ax
.
values
-
U
B
max
.
36
V DC
-
I
B
max
.
60
m
A
(
short
-
circuit proof
)
T
ransistor voltage loss
U
CE
min
. -
1
.
5
V
at
I
B
60
m
A
B
locking current
<
10
µ
A
A
djustment elements
DIL
switch block
for preadjustment of the integration time and
mode
T
est key
for function test
C
ontrol lamps in the front plate
-
status indication operating voltage
LED
green
-
S
tatus indication fault signal
LED
red
-
S
tatus indication switching point
control
LED
yellow
A
mbient conditions
A
mbient temperature
-
20
…
+
60
°
C
(-
4
…
+
140
°
F
),
with an operating
voltage of
60
…
72
V DC
the permissible
ambient temperature reduces linear from
+
60
°
C
(
+
140
°
F
)
to
+
40
°
C
(
+
104
°
F
)
S
torage and transport temperature
-
40
…
+
70
°
C
(-
40
…
+
158
°
F
)
E
lectrical protective measures
P
rotection
-
S
ignal conditioning instrument
IP
30
-
S
ocket
IP
20
O
vervoltage category
II
P
rotection class
II
E
lectrical separating measures
reliable separation
(
VDE
0106
,
part
1
)
between
power supply
,
meas
.
data input
,
level relay and
transistor output
A
pprovals
3
)
ATEX
ATEX II
(
1
)
GD
[
EE
x ia
]
IIC
O
thers
WHG
3
)
D
eviating data with
E
x applications
:
see separate safety instructions
.
32
SU
501
E
x
-
S
ignal conditioning instrument
S
upplement
27953
-
EN
-