OPERATION
4
13
OPTISYS TSS X050 SERIES
www.krohne.com
07/2018 - 4004781502 - MA OPTISYS TSSx050 R02 en
4.1 Parameterisation with display
The device is equipped with a removable display for parameterisation. Optionally for
parameterisation the PC can be used.
Even without the display, the device works as previously parameterised.
"Dsp" defines the display value. The display can show the turbidity/absorption, the temperature
in
°
C, or both values in an alternating way.
4.1.1 User menu
The device is parameterised using the function keys on the display.
The function keys are accessible after removing the housing cover.
The user menu can be opened by pressing the "Enter" button. The individual parameters can be
accessed by pressing the arrow buttons.
To configure a parameter, press the "Enter" button again, use the arrow button to select the
desired setting and confirm the selection finally using the "Enter" button.
To return back to the display after configuration, use the arrow key to move to
“
ESc
”
and press
"Enter".
Description of the user menu
The "rst" function resets all user parameters to the factory settings.
CAUTION!
Make sure that only authorised and trained personnel perform changes to the parameterisation.
INFORMATION!
Incorrect settings in the parameters may result in the output of incorrect measured values and
switching points.
Parameter
Designation
Value range
Standard value
Description
ESc
Start/end of menu
-
-
Menu input and output
-0-
(TSS 1050/
2050 only)
Reset
-
-
Resets to zero the measured or the
taught value. Same function as the
teach input.
MPr
(TSS 3050/
4050 only)
Measuring
principle
tur: turbidity
AbS: absorption
-
-
cdud
(TSS 3050/
4050 only)
Decimal place of
the user unit
0...0.000
-
Defines the decimal places of the user
unit (cdu).
cdu
(TSS 3050/
4050 only)
User unit
0...19999
-
Defines the value range of the user unit
(cdu).