DEVICE DESCRIPTION
2
11
OPTIBAR 5060
www.krohne.com
04/2021 - 4005260702 - AD OPTIBAR 5060 Exta R02 en
Category 1/2D, 1/3D equipment with temperature adapter
Range
Permissible temperature range
Electronics housing
-40...+60°C / -40...+140°F
Probe
-40...+130°C / -40...+266°F
Max. surface temperature
Electronics housing
(Z/H/A/S/T/P/F)
Ambient tempe20 K
Probe
Process tempe41 K
Table 2-5: Application for category 1/2D, 1/3D equipment with temperature adapter
(Probe: -40...+130°C / -40...+266°F)
Range
Permissible temperature range
Electronics housing
-40...+60°C / -40...+140°F
Probe
-40...+150°C / -40...+302°F
Max. surface temperature
Electronics housing
(Z/H/A/S/T/P/F)
Ambient tempe20 K
Probe
Process tempe41 K
Table 2-6: Application for category 1/2D, 1/3D equipment with temperature adapter
(Probe: -40...+150°C / -40...+302°F)
Range
Permissible temperature range
Electronics housing
-40...+60°C / -40...+140°F
Probe
-40...+180°C / -40...+356°F
Max. surface temperature
Electronics housing
(Z/H/A/S/T/P/F)
Ambient tempe16 K
Probe
Process tempe41 K
Table 2-7: Application for category 1/2D, 1/3D equipment with temperature adapter
(Probe: -40...+180°C / -40...+356°F)
Range
Permissible temperature range
Electronics housing
-40...+60°C / -40...+140°F
Probe
-40...+200°C / -40...+392°F
Max. surface temperature
Electronics housing
(Z/H/A/S/T/P/F)
Ambient tempe17 K
Probe
Process tempe41 K
Table 2-8: Application for category 1/2D, 1/3D equipment with temperature adapter
(Probe: -40...+200°C / -40...+392°F)